switch off the unit and pull the mains plug. Consult an authorised dealer for further informaaon 

and technical assistance before resuming the operaaon of the unit. 

If you are using burs which are made of tool steal (non rust proof) be sure to use a disinfectant 

which incorporates an ana-corrosive. 

Only consult authorised dealers for technical assistance, maintance or repair services! 

VIII. W

ARRANTY

 

The guarantee equals 12 months from the purchase date on which the first customer acquired 

the unit. The purchase date must be proven with a proof of purchase.   

Normal wear, e.g. on ball bearings, carbon brushes, chuck, seals etc.... is exempted. Within the 

framework  of  the  guarantee,  within  Latvia,  the  faulty  device  will  be  repaired  at  no  charge  or 

replaced  at  our  opaon.  The  prerequisite  is  postage  paid  shipping  to  us  with  the  named 

documents. Complaints in foreign countries must be directed to the representaaves within those 

countries. The guarantee is void if realized that the damage was caused by improper or wrong 

installaaon or handling, failure to comply with the instrucaons for use, external influences, or as 

a consequence of unauthorized repair or alteraaons.  

The guarantee is limited to the repair or replacement of the device. Further liability (paracularly 

loss of gains or sales) is excluded. If it is shown that the defect is not covered by the guarantee or 

the  guarantee  period  has  expired,  the  costs  of  verificaaon  and  repairs  must  be  borne  by  the 

customer. 

IX. C

ONDITIONS

 

FOR

 

TRANSPORTATION

STORAGE

USAGE

 

Transport only in the original packing of the supplier. 

Transport and storage temperature:   

 

 +  5°C  -  +50°C 

Operaang temperature: 

     

 

 

 +10°C  -  +40°C 

 

Relaave humidity:    

 

 

 

max. 90% nicht kondensierend. 

When storing the unit a|er use or when sending it to an authorised repair service please be 

aware to check all the device before shipping and to remove the used filter bags. 

 

 

14

Содержание Podo Equipment podoTRONIC OPUS III

Страница 1: ...USER MANUAL PLEASE READ THIS ENTIRE USER MANUAL CAREFULLY BEFORE USING THE MACHINE THIS IS IN ORDER TO PROTECT YOURSELF AND THE PERSON BEING TREATED AND TO AVOID DAMAGE TO THE MACHINE Version 02 04 14...

Страница 2: ...7 REDUCE SUCTION PERFORMANCE 8 MEMORY KEYS RPM MEMORY M1 M2 M3 10 CONNECTION FOR SUCTION TUBE FIRMLY CONNECTED WITH THE FILTER CHAMBER 11 REMOVABLE COVER OF THE FILTER CHAMBER COVER INCL THE CONTACTS...

Страница 3: ...ECTION FOR SUCTION HANDPIECE 7 IV ASPIRATION SETTINGS PAGE 8 1 SETTING OF SUCTION POWER 8 2 OPERATING HOURS COUNTER 8 3 FILTER CHANGE 8 4 TEMPERATURE PROTECTION OF THE SUCTION TURBINE 9 V CONNECTION O...

Страница 4: ...the best protecaon Do not operate the unit If the electric cable or plug are damaged If the unit is damaged or has been dropped Without a clean lter bag properly in place 4 Before using the unit pleas...

Страница 5: ...tecang bag and put it in the handpiece holder at the side of the unit 2 POWER CONNECTION AND SWITCHING ON Make sure that the mains cable is rmly installed and provided with a at euro plug Insert the e...

Страница 6: ...e key a speedy run of rotaaon stages will be achieved By pressing of the key the number of rotaaons can be set back in the same mode 2 ACTIVATING THE ROTATION STAND BY FUNCTION The micro switch at the...

Страница 7: ...TION DIRECTION RIGHT LEFT The preset standard direcaon of rotaaon is clockwise right rotaaon By pressing the direcaon of rotaaon can be changed 5 OVERLOAD PROTECTION FOR SUCTION HANDPIECE the motor is...

Страница 8: ...already reached on middle posiaon 60 sucaon power 2 FILTER CHANGE 1 SETTING OF SUCTION POWER 2 FILTER CHANGE 3 TEMPERATRE PROTECTION OF THE SUCTION TURBINE A PUNCTUAL FILTER CHANGE EXTENDS THE LIFE T...

Страница 9: ...essage will appear A er falling of the temperature inside the case of the sucaon turbine of approx 10 to 15 C this announcement will disappear and then the device will be in stand by condiaon TIP The...

Страница 10: ...tch the motor handpiece and sucaon will stop If a foot pedal is connected the variable speed foot control will allow you to go steplessly and very sensiavely up to the maximum speed you selected The p...

Страница 11: ...he motor jacket with a small brush and reassemble the handpiece Do not use a liquid of any kind for cleaning the inside of the handpiece 3 When reassembling the handpiece make sure to align the motor...

Страница 12: ...special drill for cleaning the chuck mechanism Carefully insert the drill into the chuck while rotaang it clockwise with your ngers and then carefully pull it out Repeat this several ames unal the chu...

Страница 13: ...water enters the housing of the unit A er cleaning the unit rub it dry using a so dry cloth Should a liquid or a foreign object of any kind nd its way into the the unit immeadiatly ONLY USE BURS WITH...

Страница 14: ...documents Complaints in foreign countries must be directed to the representaaves within those countries The guarantee is void if realized that the damage was caused by improper or wrong installaaon or...

Страница 15: ...n Dimensions controller B x H x T 320 x 125 x 220 mm Dimensions sucaon handpiece L 118 mm D 17 27 31 mm Weight ca 4 0 Kg Set Fuse T 2 5 A 115V Version T 5 A Insulaaon class 2 Typ B XI DELIVERY CONTENT...

Отзывы: