Beamz DMX 160.446 Скачать руководство пользователя страница 2

 

 

GB

 

 

WARNING 

         160.446 

 

The fog machine must be placed at least 100 cm away from inflammable materials such 
as curtains, books, etc. Make sure that the housing cannot be touched by accident.  

For indoor use only in dry rooms. 

During installation, nobody should stand beneath the mounting area. 

Prior to the first use, have the unit checked by a qualified person. 

The unit contains voltage carrying parts. DO NOT open the unit. 

Unplug the unit from the mains prior to repairs, maintenance and replacement of the lamp. 

Never plug or unplug the unit with wet hands. 

If the plug and/or mains lead are damaged, they need to be repaired by a qualified 
technician. 

If the unit is damaged to an extent that you can see internal parts, do not plug the unit into 
a mains outlet. 

Only connect this unit to an earthed mains outlet of 230Vac/50Hz and 10-16A. 

Always unplug the unit during a thunderstorm or when it is not in use.  

If the unit has not been used for a longer period of time, condensation can occur inside the 
housing. Please let the unit reach room temperature prior to use. 

When you unplug the unit from the mains always pull the plug, never the lead. 

In order to prevent dropping of the unit, a safety fastening needs to be installed. This can 

be a solid chain, a steel cable, etc. which has to be fastened separately from the mounting 
bracket. 

The supplied bracket is the main fixing and must be used to solidly mount the light effect. 

In order to avoid accidents in public premises, the local legal requirements and safety 
regulations/warnings must be fulfilled. 

Keep out of the reach of children. 

Every fog machine may produce a small quantity of fog during use and after having it 
switched on or off. 

Use this fog machine only in well ventilated places. 

Use the fog machine only for short periods of time. It is not meant for continuous use.  

 

 
 

SAFETY RECOMMENDATIONS 

 

Always connect the fog machine to a wall outlet or an earthed mains lead! Please note: the 
mains lead should only be replaced by an equivalent lead supplied by Tronios BV. 
Be careful when filling the tank. Unplug the unit from the mains first! Open the tank and fill it by 
means of a suitable funnel. 
Only use SkyTec fog fluid. This fluid is environmental friendly, biodegradable and, if properly 
used, leaves no residues. 
Do not obstruct the openings on top of the housing in order to ensure a proper cooling. The 
heat generated by the heating element must be dissipated. Do not place any objects on the 
fog machine. Do not close rooms in which this fog machine is used. A supervising person must 
always be present. 
Place the unit in such a way that there is always more than 5m free space in front of it 
otherwise there is a risk that people get in panic because they lose orientation. 
The smoke must not remain longer than 5 minutes in a room with a sight of less than 10m. 
 
 
 

 

 
 
 

Содержание DMX 160.446

Страница 1: ...DMX FOG MACHINE 160 446 INSTRUCTION MANUAL HANDLEIDING BEDIENUNGSANLEITUNG...

Страница 2: ...mounting bracket The supplied bracket is the main fixing and must be used to solidly mount the light effect In order to avoid accidents in public premises the local legal requirements and safety regu...

Страница 3: ...ct a hose to the output at the rear side Switch the pump on via the switch on the rear panel of the unit MAKE SURE THAT THE WATER IS EVACUATED EVERY DAY S OPERATION VIA THE REMOTE CONTROL First of all...

Страница 4: ...m min Heating element 1000 W Capacity of the ice tank 8 kg Capacity of the fog fluid tank 1 5 l Dimensions 450 x 355 x 683 mm Weight 19 kg Electric products must not be put into household waste Pleas...

Страница 5: ...n valt bij ophanging dient een veiligheidsophanging te worden aangebracht Te denken valt aan een deugdelijke ketting staalkabel o i d dat onafhankelijk van de beugel moet worden bevestigd De bijgeleve...

Страница 6: ...broken achtereen rook produceren Na deze periode is de rookgenerator zodanig afgekoeld dat de thermostaat uitschakelt Het verwarmingselement heeft daarna een paar minuten nodig om de rookgenerator wee...

Страница 7: ...Nu is deze weer gereed voor gebruik Als de rookmachine geruime tijd niet gebruikt wordt het reservoir niet vullen anders kan deze niet weer gevuld worden met de juiste rookvloeistof SPECIFICATIES Aan...

Страница 8: ...t werden muss Der mitgelieferte Montageb gel dient als Hauptbefestigung und muss zum soliden Aufh ngen des Ger ts benutzt werden Um Unf lle in Betrieben zu vermeiden m ssen die geltenden Sicherheitsbe...

Страница 9: ...hlt dass der Thermostat abschaltet Das Heizelement braucht dann wieder einige Minuten um den Generator wieder auf Temperatur zu bringen Wenn Sie den Nebel mit kurzen Zwischenpausen erzeugen bleibt di...

Страница 10: ...ckt gehalten wird Wenn der Tank leer ist muss die Maschine abgeschaltet werden F hren Sie nun die Fl ssigkeit genauso ab wie das Schmelzwasser Die Maschine ist nun wieder einsatzbereit F llen Sie den...

Страница 11: ...www tronios com Copyright 2010 by TRONIOS the Netherlands...