A. Master/Slave operation
The unit can be linked together in daisy chain as many as you need in master/slave mode to perform the great built-in
pre-programmed lighting shows triggered by music.
In Master/Slave mode refer to the DMX settings below:
Master unit: when working at Auto-run or Sound Control mode operation
Slave units: DMX start address MUST be set to 001. (First DIP switch = ON, all other
are OFF)
B. Easy sound active and Auto mode
Set sound active mode: Tenth DIP switch = ON , first to sixth DIP switch ON is mode of adjustable speed ,all other are OFF
Set Auto mode: Ninth and Tenth DIP switch = ON ,first to sixth DIP switch ON is speed mode ,all other are OFF
C. Universal DMX controller
When using a universal DMX controller to control the chain of units, you have to set DMX address by Dip switches from 1 to 9 to
make sure all the units will receive its DMX signal. Dip switch 10 =OFF
Please refer to the following diagram to know how to address your DMX 512 system in the binary code.
DMX 512 Address Chart:
Dip-switches # 1
# 2
# 3
# 4
# 5
# 6
# 7
# 8
# 9
#10
Value
1
2
4
8
16
32
64
128
256
2-light show
5. DMX 512 Configuration :
0: OFF / 1: ON / “- -“ means: OFF or ON
DIPSWITCH CHART
Function
1
2
3
4
5
6
7
8
9
10
Sound
--
--
0
1
Auto
Speed selection
(Slow
→
Fast)
--
--
1
1
DMX512
SET DMXADDRESS FOR DMX MODE
0
11
~
200
DMX Auto
Channel 1
201
~
255
DMX Sound
Channel 2
1
~
255
Speed(Slow
→
Fast)
Channel 3
11
~
255
Strobe(Slow
→
Fast)
Channel
4
~
~
~
~
10
0
~
255
Single-head Gobo control
Channel 11
0
~
255
All Gobos control
Master
Auto-run, Sound Control
Slave
1
0
0
0
0
0
0
0
0
0
6. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.