8
DISPLAY
Display
Mode
Function
ADDR
DMX address setting
A001-A512
CHND
Channel mode
1CH/3CH/5CH/7CH/15CH/18CH
SLND
Slave mode
Master
Slave 1 Slave 2
SOUN
Sound mode
Sound on/off
SENE
Sound sense
Sound sense 0-100
BALA
White Balance
Red 050~255
Green 050~255
Blue 050~255
BLND
Black out mode
LED mode, YES – NO
Led
LED mode
ON (led display on)
DISP
Display inversion
Display Inversion,Idsp-dspI
TEST
Test mode
Self test
TEMP
Temperature
0 ~ 9999
Hour
Using time of light
Fixture hours,0 ~ 9999
Note:
1. To the function mode you need, press Enter to confirm, press MODE about two seconds to quit.
2. The equipment can accept DMX signal whenever Auto or sound active mode, DMX is preferential.
3. Black out mode: Choose Yes, when no DMX, the unit goes to be Black out mode; Choose No, when no DMX, the
unit goes to be Sound mode.
DMX-512 CONNECTION
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the
first unit in a DMX chain. Always connect the output of one unit with the input of the next unit until all units are
connected. If you use a controller with 5 pin DMX connection you will need to use a 5-pin to 3-pin adapter.
At the last fixture, the DMX cable has to be terminated. Solder a 120 Ohm resistor between signal (-) and signal (+)
into a 3-pin XLR connector and plug this into the DMX output of the last fixture in the chain.
DMX CHANNELS
1 Channel Mode
Channel
Value
Description
1
000-007 Blackout
008-022 Show
1
023-037 Show
2
038-052 Show
3
053-067 Show
4
068-082 Show
5
083-097 Show
6
098-112 Show
7
113-127 Show
8
128-142 Show
9
143-157 Show
10
158-172 Show
11
173-187 Show
12
188-202 Show
13
203-217 Show
14