Addendum to MCS100 User Guide 

 

 

 

 

Содержание PO8C

Страница 1: ...PO8C User Guide Addendum to MCS100 User Guide ...

Страница 2: ...ot withstanding we can assume no responsibility for any errors in this manual or their eventual consequences We reserve rights to make modifications to this manual without any further notice For more detailed technical data about PO8C please refer to MCS100 User Guide or contact the manufacturer Copyright 2007 BEAMEX OY AB Ristisuonraitti 10 FIN 68600 Pietarsaari FINLAND Tel 358 10 5505000 Fax 358...

Страница 3: ...General 1 Connections 2 Specifications 3 Warnings 5 General 5 Connections 5 Pressure Regulator Specific Warnings and Notes 6 Vacuum Regulator Specific Warnings and Notes 7 Service 8 Selector Valve 8 Operation 9 ...

Страница 4: ... supply pressure Pressure adjuster for pressures above atmospheric pressure The adjuster includes a nozzle flapper type pilot valve for precise pressure adjustment Vacuum adjuster for pressures below atmospheric pressure The adjuster includes a nozzle flapper type pilot valve for precise vacuum adjustment Selector valve with four positions PRESSURE VACUUM CLOSE and VENT Adjustable volume for exact...

Страница 5: ...ds on the type of your MCS100 refer to MCS100 User Guide part A chapter Internal connections on how the supply pressure is connected to your MCS100 S u p p l y p r e s s u r e V a c u u m V e n t A d j u s t a b l e v o l u m e O u t p u t c o n n e c t o r S e l e c t o r v a l v e V a c u u m a d j u s t e r P r e s s u r e a d j u s t e r Simplified diagram of the connections on the rear side o...

Страница 6: ...ressure 10 bar 145 psi Minimum supply pressure Set pressure 0 5 bar Set pressure 7 psi Regulating pressure range 0 1 to 8 bar 1 45 to 116 psi Air consumption discharged to the atmosphere Bleed flow max ANR 1 with 10 bar 14 5 psi supply 3 5 l min 0 124 ft3 min Exhaust flow max ANR at maximum set pressure 0 9 l min 0 032 ft3 min Vacuum Adjuster Feature SI Unit Imperial Regulating pressure range2 1 t...

Страница 7: ...al Unit 0 barg 0 psig 0 46 barg 6 67 psig 7 barg 102 psig 3 37 barg 48 9 psig 0 5 barg 7 25 psig 0 73 barg 10 5 psig 0 9 barg 13 5 psig 0 94 barg 13 6 psig Output Connector The connector is delivered as shown in the leftmost picture below The connector includes an adapter to make it easy to connect pressure hoses delivered by Beamex By removing the adapter a standard ISO288 1 G 1 8 internal parall...

Страница 8: ...ge 3 Connections When connecting an instrument to PO8C s OUTPUT con nector make sure that PO8C s output pressure is not too high low to damage the instrument or any other equip ment hose being part of the pneumatic system If you open the supply valve when an instrument is con nected to the pressure output connector make sure that the pressure regulator is adjusted to a pressure that can not damage...

Страница 9: ...he Specifications starting from page 3 Close the valve of the nitrogen cylinder when the system is not in use Increase in the percentage of nitrogen in the ambient air may cause unconsciousness and death without warning Read carefully the safety instructions for nitrogen and make sure that the other people in the same space are aware of the danger Do not use the regulator outside the range its spe...

Страница 10: ...he vacuum regulator is for use of negative pressure only Be sure that positive pressure is not applied instead The vacuum regulator in itself is not damaged however the positive pressure will enter vacuum pump This may cause malfunction of the vacuum pump Note that an ejector s flow rate is smaller than that of the vacuum regulator and therefore is not suitable as a vacuum supply See Specification...

Страница 11: ...king adjustments may be required for leak tight performance Before servicing any installed valve you must depressurize the system cycle the valve and purge the valve Adjust the packing bolt clockwise in 1 16 turn increments until leak tight performance is achieved To adjust the packing remove the directional handle to see the packing bolt Then use Swagelok adapter MS WK 43 or a suitable tool to ad...

Страница 12: ...tment close the selector valve and use the ADJUSTABLE VOLUME knob Remember to make small changes and wait for the pressure to settle Changes in gas pressure affects the gas temperature and the tension volume of the measurement hoses To vent pressure turn selector valve to VENT position To avoid pressure shocks rotate the selector valve to VENT position via the regulator used for creating the press...

Страница 13: ...10 PO8C User Guide Notes ...

Страница 14: ... Internet http www beamex com Beamex Inc 2270 Northwest Parkway Suite 185 Marietta GA 30067 USA Phone 770 951 1927 800 888 9892 Fax 770 951 1928 E mail beamex inc beamex com Beamex Limited Newtown Grange Farm Business Park Desford Road NEWTOWN UNTHANK Leicestershire LE9 9FL UK Phone 01455 821 920 Fax 01455 821 923 E mail beamex ltd beamex com Representative ...