BEA WIZARD II SMR Скачать руководство пользователя страница 4

6   Mechanical Adjustments

1

Radar Motion Sensing Field: Width

1.  Insert the desired microwave antenna for a wide or narrow 

fi

 eld of detection. The optional narrow 

fi

 eld antenna is located in the slot behind 

the mounted antenna as shown. To remove the antenna, carefully remove the protective cover and change the antenna. Once the proper 

antenna is in place, adjust the angle of antenna as necessary.

0

3.2’ 6.4’

3.2’

6.4’

0

3.2’

6.4’

9.6’

0

3.2’ 6.4’

3.2’

6.4’

0

3.2’

6.4’

9.6’

Wide Pattern

Narrow Pattern

2

Radar Motion Sensing Field: Depth

1.  The position of the sensing 

fi

 eld is determined by the vertical angle of the planar antenna. The angle is adjusted by gently rotating the 

antenna forward or backward.  The default angle is 30°.

2.  The tilt angle is determined by the position of the sensor with relation to the face of the door. A 15° angle will result in the pattern being drawn 

back toward the door. A 45° angle will place the pattern further away from the door. Be certain to walk test the detection 

fi

 eld and ensure 

compliance with applicable ANSI standards.

0

3.2’ 6.4’

3.2’

6.4’

0

3.2’

6.4’

9.6’

0

3.2’ 6.4’

3.2’

6.4’

0

3.2’

6.4’

9.6’

13.1’

15° 30° 45°

30°

45°

15°

3

IR Presence Sensing Field: Width

1.  Install the lens for the desired IR pattern. The wide pattern offers 2 curtains of 24 overlapping spots and the narrow pattern offers 2 curtains of 

12 overlapping spots. When installing the lens ensure the smooth part of the lens is installed facing outward.

6.5’

14”

7.2’

3.2’

14”

7.2’

Wide Pattern

Narrow Pattern

4

IR Presence Sensing Field: Depth

1.  The IR pattern may be adjusted by moving the pattern nearer or further away from the face of the door by adjusting the tilt angle from +4° to 

-4°. A counterclockwise rotation of the adjustment screw will move the curtain further away from the door and clockwise rotation will move the 

curtain toward the door. Precise location of the IR beam may be found by using BEAs Spot

fi

 nder P/N 10SPOT.

-4°

max. 3”

max. 3”

+4°

-4°

Sensor Plastic Pin Indicator

Sensor Adjustment Screw

Page 

of 

13 

          

75.5122.05 

20070427

OBSOLETE

Содержание WIZARD II SMR

Страница 1: ...55 lbs 250 g Housing material ABS LURAN S Color of Housing Anthracite gray standard aluminum or white finish Cable length 10 of 9 conductor cable 2nd Radar Antenna Radar Motion Sensor Radar Antenna Clip Radar Tilt Angle Indication 15 30 45 Cover Push Buttons IR Presence Sensor IR Prism Main Connector IR Curtain Adjustment Screw DESCRIPTION MOTION SENSOR PRESENCE SENSOR Technology Microwave and mic...

Страница 2: ...uipment ensure the correct line voltage and stability When applying equipment on a new installation utilizing new electrical supply circuits always ensure that correct line voltage exists and is stable Remember to shut the power back off after this is checked and before performing any wiring to the system 5 Installation 1 Remove Sensor Cover 1 Remove cover from unit by gently prying the tab on the...

Страница 3: ...ilot holes for screw mounting NOTE Flush mount with bottom of header is necessary for all negative IR angles 2 Mount the sensor at a maximum height of 2 from the bottom line of the door operator 3 Insert mounting screws approximately halfway in and install the Wizard on the screws When in place tighten screws to secure to header NOTE Leave cover off until mechanical adjustments are complete 3 Cabl...

Страница 4: ...pattern further away from the door Be certain to walk test the detection field and ensure compliance with applicable ANSI standards 0 3 2 6 4 3 2 6 4 0 3 2 6 4 9 6 0 3 2 6 4 3 2 6 4 0 3 2 6 4 9 6 13 1 15 30 45 30 45 15 0 3 IR Presence Sensing Field Width 1 Install the lens for the desired IR pattern The wide pattern offers 2 curtains of 24 overlapping spots and the narrow pattern offers 2 curtains...

Страница 5: ...shes Quickly Press Question Mark The Number of Green Flashes Indicate the Value of This Parameter RED LED Flashes Slowly Press Lock Key Twice OR Lock Code 0 9 0 9 0 9 0 9 1 4 7 F1 F2 5 8 0 3 6 9 2 Relay Hold Time 0 0 5s 9 9s Sensitivity 0 min 9 max default 7 0 3 6 9 0 3 2 6 4 3 2 6 4 0 3 2 6 4 9 6 Microwave Detection Mode 1 Bidirectional Mode 2 Unidirectional Mode 3 Unidirectional Mode with MTF 4 ...

Страница 6: ...mmended for first time set up Duration is 16 seconds and will automatically trigger door to open position during set up routine Microwave Immunity Immunity levels above 3 are intended for applications where excessive interference may be causing unintended detection When applying a value of 4 or higher increment the value one step at a time followed by a walk test When complete ensure compliance wi...

Страница 7: ... RED LED PARAMETER VALUES Altered by the left button and confirmed by GREEN LED DEFAULT VALUE 1 Radar Sensitivity 0 9 7 2 Relay hold time 0 9 0 3 Output configuration 1 4 4 4 Auto learn presence sensing 0 9 0 5 Detection mode 1 4 3 6 Microwave Immunity 1 9 3 7 IR Immunity 1 3 2 8 Not Used Displays 8 Orange Flashes Displays 8 Orange Flashes 9 SMR mode 0 1 0 10 IR curtain 1 3 3 11 Secondary Sensitiv...

Страница 8: ...Wizard 3 Faulty Power Input 1 Launch a new setup and remain all clear from the detection area 2 Remove power then re apply Input power may have fluctuated beyond tolerances Red LED on at Wizard 1 Wizard in detection 1 If red LED is on at Wizard a Adjust infrared pattern away from the door and launch a new set up Refer to page 5 for infrared adjustments Use BEA Spotfinder to accurately adjust the p...

Страница 9: ...emote are dead or are installed improperly 1 Ensure batteries are installed correctly Replace batteries AAA 1 5 volt Wizard will not unlock when access code is entered 1 Improper code being entered 1 Reset code to the default value of 0000 by performing the following a Cut and restore power supply No code is required to unlock during the first minute after powering Reset code prior to locking Red ...

Страница 10: ...4 5 NC 4 NO 3 COM 2 12 24 VAC DC 1 12 24 VAC DC RB WH 1 RB BL 2 EB WH 3 EB BL 4 RECEIVER A EMITTER A RECEIVER B EMITTER B WH WHITE BL BLACK MICROCELL ONE ON 1 2 3 4 RA WH 1 RA BL 2 EA WH 3 EA BL 4 5 NC 4 NO 3 COM 2 12 24 VAC DC 1 12 24 VAC DC RB WH 1 RB BL 2 EB WH 3 EB BL 4 RECEIVER A EMITTER A RECEIVER B EMITTER B WH WHITE BL BLACK MICROCELL ONE ON 1 2 3 4 IF AFTER TROUBLESHOOTING A PROBLEM A SAT...

Страница 11: ...tional connect to reset TB1 R if required LOCKING DEVICE TITLE BESAM CUD J 9 AMD2 SLIDING DOOR WITH WIZARD II SYSTEM NOTE 1 DO NOT CONNECT BROWN WIRES TO C SWITCH COMMON 2 OBSERVE POLARITY WITH BROWN CONNECTING TO GROUND 0 VDC 3 A JUMPER MUST BE INSTALLED IN PINS 9 12 ON CONTROL BOX FOR RE ENTRY SENSOR IN ONE WAY TRAFFIC AS PER APPLICABLE ANSI STANDARD IF AFTER TROUBLESHOOTING A PROBLEM A SATISFAC...

Страница 12: ... CONNECTED TO GROUND 0 VDC 3 A JUMPER MUST BE INSTALLED BETWEEN PINS 5 12 ON THE CONTROL BOX TO ALLOW FOR RE ENTRY SENSOR IN ONE WAY TRAFFIC MODE TO COMPLY WITH ANSI A156 10 SECTION 8 3 3 4 CAN POWER SENSOR FROM CONTROL BOX 24 V TRANSFORMER IF AFTER TROUBLESHOOTING A PROBLEM A SATISFACTORY SOLUTION CANNOT BE ACHIEVED PLEASE CALL B E A INC FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1 80...

Страница 13: ...6 7 8 9 10 11 12 13 14 15 16 INTERIOR SW EXTERIOR SW COMMON SAFETY BEAM COMMON TOGGLE SW COMMON CLS MON SW COMMON PARTIAL OPEN 2WAY 1 WAY NIGHT SW COMMON DAY NITE SW 24VDC 24VDC C2150 CONTROL WIZARD EXTERIOR WIZARD INTERIOR IF AFTER TROUBLESHOOTING A PROBLEM A SATISFACTORY SOLUTION CANNOT BE ACHIEVED PLEASE CALL B E A INC FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1 800 523 2462 FROM 8...

Отзывы: