BEA VIO-D Скачать руководство пользователя страница 2

1

2

3

0

1

2

1

2

0

1

2

3

3

3

0

1

2

1

2

0

1

2

3

3

3

«click»

12-30 V DC

1

1

VIO-DT 1&2

H

W

H

W

2 m

1 m

max. 
5 cm

MIN

MAX

max. 5 cm

+

-

+

-

2.2 m

2.2 m

field size: max

4 x 2 m

1 x 0.5 m

MOUNTING & WIRING

RADAR FIELD - OPENING IMPULSE

FIELD SIZE

ANGLE

GREEN
LED

RED
LED

1

 Output status when sensor is operational 

2

 For compliance with EN 16005, connection 

 to door controller test output is required.

2.2 m

The door control unit and the door cover profile must be correctly earthed. 

Check position of IR-curtains with 
Spotfinder and adjust if necessary.

ANGLE

Detection field width indicated according to conditions defined in EN 16005 and including dimension of test body CA.

A

vailable as accessory

INFRARED FIELD - SAFETY

WIDTH

    

H

            

W

2.20 m    2.30 m
2.50 m    2.55 m
3.00 m    2.80 m

    

H

            

W

2.20 m    1.20 m
2.50 m    1.40 m
3.00 m    1.60 m

* in standard presetting

GREEN

BROWN

YELLOW

WHITE

PINK

GREY

RED

2

BLUE

2

POWER SUPPLY

OPENING INPUT

OPENS DOOR

SAFETY INPUT

KEEPS DOOR OPEN

TEST
OUTPUT

RELAY R1

RELAY R2

DOOR

CLOSER

AWAY

SE

NS

OR

The size of the detection field varies according to the mounting height of the sensor. 

ORANGE

@ 2.2 m:
Depth of curtain : 8-10 cm
Depth of safety field: 25 cm*

Содержание VIO-D

Страница 1: ...sor at least once per door cycle EN 61508 SIL2 EN 61496 1 ESPE Type 2 EN 12978 EN 16005 Supply voltage Power consumption Mounting height Sensitivity of the test input Temperature range Degree of protection Noise Expected lifetime Conformity Motion Min detection speed 5 cm s Microwave doppler radar Transmitter frequency 24 150 GHz Transmitter radiated power 20 dBm EIRP Transmitter power density 5 m...

Страница 2: ...ition of IR curtains with Spotfinder and adjust if necessary ANGLE Detection field width indicated according to conditions defined in EN 16005 and including dimension of test body CA Available as accessory INFRARED FIELD SAFETY WIDTH H W 2 20 m 2 30 m 2 50 m 2 55 m 3 00 m 2 80 m H W 2 20 m 1 20 m 2 50 m 1 40 m 3 00 m 1 60 m in standard presetting GREEN BROWN YELLOW WHITE PINK GREY RED2 BLUE2 POWER...

Страница 3: ...ions PRESETTINGS ENVIRONMENT RELAY R1 ACTIVATION SAFETY INSTRUCTIONS TIP Launch an ASSISTED SETUP to verify wiring position of the curtains and correct functioning of the sensor SETTINGS by DIP switch QUICK SETUP ASSISTED SETUP SETUP Step outside of the infrared field before launching a setup LONG 3s SHORT standard critical environment shopping street1 hospital2 standard extreme3 1 Can only be use...

Страница 4: ...The sensor encounters a memory problem The sensor vibrates The sensor sees the door during the assisted setup The sensor sees the door The sensor is disturbed by lamps or another sensor The sensor is disturbed by the rain The sensor is disturbed by rain and or leaves The sensor vibrates Ghosting The sensor sees the door or other moving objects Check power supply Check wiring Use the 1 m prism if p...

Отзывы: