FlexIR Technical Specifications

Materials:
Flexible Beam Holder

Silicone

Mounting Brack

Galvanized Steel

Button Plug

ABS and Lexan

Screws

18/8 Stainless Steel

Dimensions:
Overall Length

6” (150 mm)

Width (of Bracket)

1 ¾” (45 mm)

Height (of Bracket)

2 ¾” (70 mm)

Installation Height

See Mechanical Installation 
Instructions in User’s Guide

Operating Temperature -30° to + 131° F

Bracket when used with Microcell (sold separately)
Minimum Distance 
between pairs of beams 
12” (beams must not be crossed)
Range of Detection
Minimum

3’ (1 m)

Maximum

16.5’ (5m) if mounted 8” (0.2m) 
above ground
33’ (10m) if mounted 16” (0.4m) 
above ground

Minimum Distance
from Plane of Door

1”(25.4 mm)

Alignment Tolerance

www.beasensors.com

Contact Information

BEA Inc.

RIDC Park West

100 Enterprise Drive

Pittsburgh PA, 15275

Phone +1.412.249.4100

Fax +1.412.249.4101

Toll Free 1-800.523.2462

BEA West

2401 Pine Street

Los Angeles, CA 91767

Phone +1.909.596.3011

Fax +1.909.596.5411

Toll Free 1-877.232.9378

SBK30

LO Linx

3

1

2

5

4

Flex IR Components

Phillips Head Screw (6)
Mounting Box
Flexible Beam Holder
Button Plug
Microcell Beam
NEMA 4 Accessory

1

2

3

4

5

Applications

Flex IR protects the microcell against blunt hits from 

tractor trailers, forklifts, or heavy objects in the 

industrial setting.

Flex IR with Microcell provides safety accross garage 

door openings to help prevent injuries from a closing 

garage door. The Flex IR protects the microcell from

getting hit by cars or other heavy objects. 

6