![BEA MAGIC SWITCH MS09 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/bea/magic-switch-ms09/magic-switch-ms09_quick-start-manual_2715853002.webp)
1
1
2
NC
–
yellow
NO
–
green
POWER
–
red (12 – 24 VAC/VDC)
POWER
–
black (12 – 24 VAC/VDC)
COM (at door control)
–
white
Page 2 of 4
75.5746.05 MS09 20210115
INSTALLATION
WIRING
AP
PLI
C
A
TI
O
N
S
Swing Doors
Sliding Doors
Connect the existing 2 wires running through the wall (previously used for the activation relay of the
hardwired, mechanical push plate) to the MS09 sensor’s PWR (black) and PWR (red) terminals.
At the door control, move the 2 wires from the activation circuit to power (see Technical Specifications for
power information).
TI
PS
Industrial Doors
Cleanrooms
Only trained and qualified
personnel are recommended to
install and set up the sensor.
The warranty is invalid if
unauthorized repairs are made
or attempted by unauthorized
personnel.
Always test the proper
operation of the installation
before leaving the premises.
PRECAUTIONS
• Run conduit prior to installing sensor.
• Fully adjust sensor after entire installation is complete.
NOTE:
Do not install the sensor within the swing path of the door.