BEA LZR-U920 Скачать руководство пользователя страница 3

75.5847.03 LZR-U920_U921 20191125 

 

Page 3 of 4

1

2
3

4
5

6

1

2

3

4

a

d

e

b

c

7

DESCRIPTION

1. 

laser window – emission

2. 

laser window – reception

3. 

LED signals (4)

4. 

holes for M5 screws

5. 

holes for Ø UNC N°10 screws

6. 

cable conduit 

7. 

visible laser beams (3)

LED SIGNAL

LED 1

LED 2

on and running

(green)

transmitting distance data

(green)

ERROR LED

POWER LED

configuration mode

(red)

idle / transmitting heartbeat

(red)

no error

(off)

error

(orange)

no power

(on)

power

(blue)

1.  LED 1
2.  LED 2
3.  Error LED
4.  Power LED

MOUNTING & WIRING

Use the mounting template to 
position the sensor correctly. 
The gray area indicates the 
detection range.

Pass the cable through the 
cable opening.

Drill 3 holes as indicated on 
the mounting template. 
Drill a hole (1/2 inch min.) for 
the cable.

Position the sensor and secure using the 
provided M5 or 

Ø

 UNC N

°

10 screws.

Wire accordingly.

If the heartbeat mode1 via the brown/white and brown wire is 

not used, it is recommended to ground these wires.

max. 

8 mm

For more information on existing parameters that can be configured,  

see Application Note 

LZR

®

-U920/U921 Protocol

 (76.0019).

WIRE COLORS

FUNCTION

Power supply (10 – 35 VDC)

Red (+)

Black (-)

bare

Blue (+)

Blue/White (-)

Brown/White

Brown

GND

RS485B
RS485A

ISSD1 PIN 1*
ISSD1 PIN 2*

Содержание LZR-U920

Страница 1: ...75 5847 03 LZR U920_U921 20191125 Page 1 of 4 LZR U920 U921 LASER MEASUREMENT DEVICE WITH BI DIRECTIONAL BUS COMMUNICATION User s Guide EN Visit website for available languages of this document ...

Страница 2: ...and light sources in front of the laser window Avoid the presence of smoke and fog in the detection field Avoid exposure to sudden and extreme temperature changes Keep the sensor permanently powered in environments where the temperature can drop below 35 F Do not use aggressive products to clean the laser windows Avoid direct exposure to high pressure cleaning Clean the laser window with compresse...

Страница 3: ...NG Use the mounting template to position the sensor correctly The gray area indicates the detection range Pass the cable through the cable opening Drill 3 holes as indicated on the mounting template Drill a hole 1 2 inch min for the cable Position the sensor and secure using the provided M5 or Ø UNC N 10 screws Wire accordingly If the heartbeat mode1 via the brown white and brown wire is not used ...

Страница 4: ...isible laser wavelength 635 nm output power 0 95mW CLASS 2 Supply voltage 10 35 V DC sensor side Power consumption 5 W Peak current at power on 1 8 A max 80 ms 35 V Serial communication Type Interface Communication mode Transmission speed Topology Symbol coding File type see Application Note LZR U920 U921 Protocol 76 0019 asynchronous RS 485 half duplex 460800 bit sec max 921600 bit sec point to p...

Отзывы: