BEA LZR-MICROSCAN U920 Скачать руководство пользователя страница 4

4

1

2

1

2

3

4

MOUNTING

WIRING

INSTALLATION STEPS

Use the adhesive mounting template to 

position the sensor correctly. The grey 

area indicates the measurement range.

Drill 2 holes as indicated on the 

mounting template. Make a hole for 

the cable.

Pass the cable through the cable hole. 

Position the sensor and fasten 

the screws firmly.

Use M4 screws 

For more information see application note LZR

®

 

-MICROSCAN U920 Protocol or contact BEA. 

Shield

Green

Brown

Yellow

Gray

Violet

Pink

GND

V+

V-

RS485A(RX+)

RS485B(RX-)

RS485Z(TX-)

RS485Y(TX+)

Содержание LZR-MICROSCAN U920

Страница 1: ...1 EN LZR MICROSCANU920 LASER MEASUREMENT DEVICE WITH BIDIRECTIONAL BUS COMMUNICATION User s Guide for product version 0100 and more ...

Страница 2: ......

Страница 3: ...d responsible for incorrect installations or inappropriate adjustments of the device LASER MEASUREMENT DEVICE 1 laser sweep emission 2 laser sweep reception 3 LED signal 4 5 6 cable conduit LED SIGNAL Has been switched ON and keep running in measurement mode error In configuration mode 4 6 reset button take of the cover and internal shroud holes for M4 screws ...

Страница 4: ...range Drill 2 holes as indicated on the mounting template Make a hole for the cable Pass the cable through the cable hole Position the sensor and fasten the screws firmly Use M4 screws For more information see application noteLZR MICROSCAN U920 Protocol or contact BEA Shield Green Brown Yellow Gray Violet Pink GND V V RS485A RX RS485B RX RS485Z TX RS485Y TX ...

Страница 5: ...osure to sudden and extreme temperature changes Keep the sensor permanently powered in environments where the temperature can descend below 15 C Wipe the front screens regularly with a clean and damp cloth Do not use aggressive products to clean the front screens Avoid direct exposure to high pressure cleaning CAUTION Use of controls adjustments or performance of procedures other than those specif...

Страница 6: ...x 10 m 3 m 5 remission factor 10 m 55 remission factor max 4 max 40 min 2 56 max 100 1500 turns min 25Hz 2 wavelength 905 nm max output pulse power 75 W CLASS 1 12 24 VDC AC 10 4 W 1 5 A max 30 ms 24 V see AN LZR MICROSCAN U920 Protocol asynchronous RS 422 half duplex 921600 bit sec default point to point 1 start bit 1stop bit no parity bit 8 bits 3 m 1 bi coloured LEDs function status 118 mm D x ...

Страница 7: ...k the power supply voltage Verify the outside temperature where the sensor is installed Eventually protect the sensor from sunlight using a cover Wait a few seconds If the LED remains ON reset the power supply If the LED turns on again replace the sensor Enable LED by command The orange LED flashes 3 times EEPROM error Open the cover Keep pushing RESET button for more than 2 seconds Repower the se...

Страница 8: ...CROSCAN U920 is in conformity with the basic requirements and the other relevant provisions of the directives 2006 95 EC 2011 65 EU and 2004 108 EC Angleur June 2013 Pierre Gardier authorized representative For EU countries This product should be disposed of separately from unsorted municipal waste BEA 4 5th Floor M8 Building No 1 Jiuxianqiao East Road Chaoyang District Beijing CHINA T 86 10 57761...

Отзывы: