75.5897.02 LZR-H110 20170821
Page 7 of 12
SAFETY FIELD
–
PRESENCE
5
-
-
MIN
MAX
+
WIDTH
DEPTH
0.5 m
6.5 m
2.0 m
0.5 m
5.0 m
EX:
for a field width of 6.2 m
Adjust the field dimensions if you want to get a rectangular field.
auto-set to
reference point
max. 30 s
Wait for the sensor to learn its environment.
During the teach-in (30 sec.), the sensor records the reference distances to all objects within its detection zone.
If you walk along the detection area while the teach-in function is active, the sensor memorizes the outline of the
walk path and stores this as a new detection field. The shortest distance measured by each laser beam is stored by the
sensor and determines the field limit.
Once the sensor has finished the teach-in, make sure that the safety field is correctly configured and that the area
around the barrier or gate is safe.
You can increase or decrease the field by 10 cm:
The safety field can be adapted more precisely by launching a teach-in (the sensor learns the environment).
Before launching a teach-in, make sure that the selected field size is bigger than the desired field size.
The detection field should be free of snow buildups, heavy rain, snowfall, fog, or other moving objects.
3 s
FIELD DIMENSIONS
TEACH-IN
Always launch a new teach-in after adjusting the field dimensions.
WIDTH
6.5 m
The safety field is necessary for the correct functioning of the installation. If the safety field is too small,
the manufacturer of the sensor cannot be held responsible for inappropriate functioning of the installation.
2 m
75.5897.02 LZR-H110 20170821
Page 7 of 12
OBSOLETE