BEA hereby declares that the LZR®-FLATSCAN RS305 is in compliance with European directives 2014/30/EU and
2011/65/EU. The full text of the EU declaration of conformity is available on our website
for
ec
countries
:
this
product
should
be
disposed
of
separately
from
unsorted
municipal
waste
.
SAFETY INSTRUCTIONS
The manufacturer of system is responsible for carrying out a risk assessment and installing the scanner and the system in compliance
with applicable national and international regulations and standards.
Only trained and qualified personnel may install and setup the scanner.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Avoid touching any electronic and optical components.
TECHNICAL SPECIFICATIONS
©
BE
A
|
O
ri
gi
na
l i
ns
tr
uc
ti
on
s
|
69
.1
11
8/ V
7-
20
21.
07
BEA
/
A-B Area, 3rd Floor, No.1 Building
/
No.5 Xinghai Road, Beijing Economic Technological Development Area, Beijing
/
CHINA
T
+86 10 5776 1630
/
F
+86 10 6262 8775
/
E
/
W
asia.beasensors.com
Technology
LASER scanner, time-of-flight measurement
Detection mode
Presence
Max. detection range
Max. 5.5m*5.5m (4m@5% reflectivity)
Opening angle
90°
Angular resolution
0.23° (400 spots within 90°)
Testbody
700mm x 300mm x 200mm (for your reference)
Emission characteristics
Wavelength 905nm; Max. output pulse power 25W (CLASS 1)
Wavelength 635nm; Max. output CW power 0.95mW (CLASS 2) Visible spot
Supply voltage
12-24V DC ± 15%
Power consumption
≤ 2.3W, peak current: 1A
Response time
Max. 50ms (+ output activation delay)
Output
1 opto (galvanic isolation - polarity free)
Max. switching voltage: 42V AC/DC
Max. switching current: 100mA
1 Relay (free of potential contact)
Max. contact voltage: 42V AC/DC
Max. contact current: 1A (resistive)
Max. switching power: 30W DC/60VA AC
LED-signals
1 tri-colored LED: detection / output status
Dimensions
124mm (L) × 90mm (H) × 50mm (D) (without bracket)
Colour
Black
Tilt angles
±3° (with bracket)
Protection degree
IP66 (EN 60529)
Temperature range
-30°C to +60°C if powered
Humidity
0-95% non-condensing
Vibrations
< 2G
Norm conformity
IEC 60825-1; EN 60950-1; EN 61000-6-2;
EN 61000-6-3; EN 60529:2001; EN 50121-3-2:2006
Specifications are subject to change without prior notice. All values are measured in specific conditions.