3
C A
B
cm
cm
cm
001 - 070
001 - 500
001 - 070
4
6
no field
no field
no field
h =
installation height
Automatic teach-in
With the remote control
Use the remote control to define the left width C and right width A, then launch an environment learning.
( + + ). LED goes off after finishing the environment process. No need to define the width of the
field with your hand in this mode.
FRONT FACE
DETECTION ZONE SETTING & TEACH-IN
Set the detection range either automatically or with the remote control:
1.
To launch a teach-in, press shortly (< 2 sec) the push button (or by remote control + + ).
The sensor starts flashing red-green quickly and automatically learns the installation height.
2.
Wait until the sensor flashes green. Stretch out your arm in front of you and make an up and down
movement to define the left/right limit of the detection field. The LED flashes red while calculating.
3.
Wait until the sensor flashes green again. Stretch out your arm in front of you and make an up and down
movement to define the right/left limit of the detection field. The LED flashes red while calculating.
4.
Once the LED is off, the teach-in is completed.
Clasp the front cover to finish the installation.
Protect the laser window in case of construction works.
• h < 3.5m, the sensor can detect testbody CA (EN 16005 & DIN 18650-1) and CB (DIN 18650-1).
• 3.5 < h < 4m, the sensor can detect tesbody CA (EN 16005 & DIN 18650-1),
but the testbody CB (DIN 18650-1)
might not be detected.
• h > 4m,
the testbodies CA (EN 16005 & DIN 18650-1) and CB (DIN 18650-1) might not be detected
Left
detection
area
Right
detection
area
< 2 sec.