BEA IS40 Скачать руководство пользователя страница 9

14

1

4

7

F1

F2

5

8

0

+

?

3

6

9

2

A

B

C

D

15

16

Application requires an access 

code or sensor will not unlock

after entering an access code.

You must enter a code or the wrong 

code was entered.

Cycle the power. No code is required to 

unlock during the first minute after pow

-

ering on. Unlock, then lock and enter a 

new access code or “0000” to delete the 

current access code.

TROUBLESHOOTING (CONTINUED)

SYMPTOMS

POSSIBLE CAUSES

CORRECTIVE ACTION

The green LED is on during rain 

or snow.

The sensor detects objects 

outside of its detection field.

The sensor does not respond to 

the remote control.

The microwave detection is disturbed 

by  the rain or snow.

To much reflection due to a metallic 

environment.

The batteries in the remote control are 

not installed properly, dead or the re-

mote is poorly aimed.

Increase the microwave rejection.

Consider using the unidirectional mode 

under the Detection Mode.

Increase the microwave rejection.

Verify or replace batteries or aim remote 

towards sensor.

The sensor is not powered.

Check the power supply of the sensor.

ACCESSORIES

Spotfinder

P/N: 10SPOTFINDER

Remote control

P/N: 10REMOTE

Telescoping HD Bracket

P/N: 10HDBRACKET

COMPANY CONTACT

Our Service Technicians can be called 24 hours a day, 7 days a week. For more information visit www.beasensors.com. 

Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting

a problem, please call BEA, Inc. If you must wait for the following workday to call BEA, leave the door

inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic

door or gate for an incomplete solution. 

After Normal Business Hours

West / Mexico

1-888-419-2564

Central

1-800-407-4545

AK, MI, WI, TX, Canada

1-866-836-1863

East

1-866-249-7937

Phone: 1-800-523-2462

Fax: 1-888-523-2462

For email support contact us at: [email protected]

Transformer

P/N: 1024VAC

75.5695.01  EN   20120113   

 

 

 

 

 

 

 

Page 9 of 9

Содержание IS40

Страница 1: ...4 175 GHz 875 nm RADIATED POWER DENSITY 5 mW cm 250mW m DETECTION MODE Motion Presence MAXIMUM DETECTION FIELD IS40 13 ft x 16 ft 4m x 5m IS40XL 13 ft x 6 5 ft 4m x 2m IS40 10 ft x 10 ft 3m x 3m IS40XL 7 5 ft x 7 5 ft 2 3m x 2 3m OUTPUT HOLD TIME 0 5 sec to 9 sec 0 5 sec REACTION TIME 100ms 250ms MINIMUM TARGET SPEED 2 in sec 5cm sec in sensor axis 0 in sec 0cm sec LED SIGNAL Green Activation Rela...

Страница 2: ...ith all applicable safety standards upon completion of installation DO NOT attempt any internal repair of the sensor All repairs and or component replacements must be performed by BEA Inc Unau thorized disassembly or repair 1 May jeopardize personal safety and may expose one to the risk of electrical shock 2 May adversely affect the safe and reliable performance of the product and will result in a...

Страница 3: ...llustration purposes and represent an approximate IR detection field when at 16 ft The point of emphasis is to show the IR detection area with respect to the sensor angles SENSOR ANGLE COM NO NC RED BLACK 12 24 V AC DC WHITE GREEN YELLOW WHITE BLACK GREEN BLACK YELLOW BLACK COM NO NC Green LED Motion Red LED Presence 1 4 Activation Relay Presence Relay 1 Active Passive 2 Passive Active 3 Passive P...

Страница 4: ...ELD ADJUSTMENTS Adjust the Microwave field size Refer to page 5 Choose the correct rejection mode for your application Refer to page 6 By turning this dial the radar field angle is reduced or increased from 8 to 22 Refer to page 5 Mounting Height Width Depth A 8 ft 5 ft 5 ft B 10 ft 7 ft 7 ft C 11 5 ft 7 5 ft 7 5 ft D 13 ft 8 5 ft 8 5 ft E 16 ft 10 ft 10 ft Maximum Mounting Height IS40XL 11 5 ft I...

Страница 5: ...5 of 9 MICROWAVE FIELD TILT ANGLE Sensor angle 30 Radar field angle 8 Total angle 22 Sensor angle 30 Radar field angle 0 Total angle 30 Sensor angle 30 Radar field angle 11 Total angle 41 The total angle is the sum of the sensor angle and the radar field angle All detection field dimensions were measured in optimal conditions and a sensitivity value of 7 Sensor angle 30 Radar field angle 8 Total a...

Страница 6: ...Activates if object motion is detected and then object exits presence zone first or last line 5 REMAINS ACTIVE UNTIL PRESENCE ZON E IS CLEARED Regardless of Motion Activates when motion is detected and remains active until the presence zone is cleared 6 REMAINS ACTIVE UNTIL PRESENCE ZONE IS CLEARED Regardless of Motion Activates when motion is detected and IR is detected and remains active until t...

Страница 7: ... 7 5 6 2 5 6 5 2 1 7 5 1 1 1 2 1 7 5 2 1 7 5 2 1 5 2 3 4 7 5 6 1 2 3 4 7 5 6 1 Factory values 75 5695 01 EN 20120113 Page 7 of 9 IR Presence Settings Continued IR PATTERN SIZE AVAILABLE TARGET SIZE 1 2 3 4 5 9 8 7 6 The target Target Size can vary location within the field IR Pattern Size ...

Страница 8: ...n time to expire and or Launch a setup The red LED is on during rain or snow The red LED is permanently on after a setup The door keeps recycling open or closed The presence detection is disturbed by the rain or snow Setup has failed due to motion in the IR field during setup The sensor detects door vibrations or environmental disturbances Increase the immunity of the IR field value 2 or 3 respect...

Страница 9: ...l mode under the Detection Mode Increase the microwave rejection Verify or replace batteries or aim remote towards sensor The sensor is not powered Check the power supply of the sensor ACCESSORIES Spotfinder P N 10SPOTFINDER Remote control P N 10REMOTE Telescoping HD Bracket P N 10HDBRACKET COMPANY CONTACT Our Service Technicians can be called 24 hours a day 7 days a week For more information visi...

Отзывы: