Use the chart below as an aide for the manual programming procedure. 

 

 

Manual Setup Of The Sensor – continued

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

REQUIRED:  If the IR frequency has been manually changed, to prevent the sensors from being in permanent 

detection, momentarily depress the right program button to launch an assisted setup. 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 
 

High mounting height 

(>10’) 

 

If the sensor is installed higher than 10’ above the floor, make sure to use the narrow prism  
(See Ch. 3).  

 

   

Rain/Snow 

 

If the sensor is exposed to rain or snow, use the URC (Universal Rain protection Cover) 

 

Set the sensor to immunity level 2 or 3 to increase the immunity of the sensor.  

 

   

Setup 

 

 

  Assisted Setup (~14sec) 

Sensor checks the influence of the door leaves to the IR 
curtains (performs a door open/door close cycle) 

 

 

Standard Setup (~4sec) 

Sensor only learns its environment 

After adjusting the sensor for the first time, it is required to launch an ‘Assisted Setup’ (See Ch. 4). 
If the IR sensor module ‘sees’ the door movement, move the curtains out of the door leaf. 

 

   

Access Code 

 

The access code is recommended to set sensors close to each other with remote control. The access code can 
be composed of 1 to 4 digits (factory values or no access code : 0 or 0000). No code is required to unlock during 
the first minute after powering. To enter a lock code, simply press the Lock key, followed by a lock code. If lock code is 
less than 4 digits, the lock key must be pressed a second time following the last digit of the code (See Pg. 5).

 

 

   

Overlapping  
IR-curtains 

 

Overlapping IR-curtains from sensors installed side-by-side may cause disturbances due to crosstalk 
(interferences). Select different frequencies on each sensor to avoid crosstalk (See Setting ‘Installation 
Configuration’ on Pg.6). 
Attention: avoid curtains that are overlapping by more than 12” (at 7’ mounting height, using the wide prism).

 

 

   

 

 
 
 
 
 
 
 
 
 

 
PARAMETER NUMBER 

(altered by the right button and 
confirmed by 

RED LED

 
PARAMETER 

 
VALUES 

(altered by the 
left button and 
confirmed by 

GREEN LED

 
DEFAULT 
VALUE 

1 Not 

Used 

Relay hold time 

3 Output 

configuration 

1-4 

Auto-learn  
presence sensing 

0-9 

0 = IRIS 

9 = IRIS-I 

5 Not 

Used 

6 Not 

Used 

7 IR 

Immunity  1-3 

Not Used  

9 Not 

Used 

10 IR 

curtain 

1-2 

11 Not 

Used 

12 

Height & Frequency 

1, 3 

13 Not 

Used 

14 

Door control function 

1-3 

15 Not 

Used 

5 Helpful 

Hints 

Содержание IRIS

Страница 1: ...elay Configuration By default it is set to Active value 4 the IRIS relay contact closes upon detection If passive is required change the output configuration value to 1 The most obvious indication to this condition is that the door works in reverse order no detection results in hold open Pulse Frequency If an interference is suspected from other nearby sensors or IR equipment change the frequency ...

Страница 2: ... 8 oz Housing material ABS LURAN S Minimum length of cable 10 3 m 9 conductor 10IRIS 30 9 m 9 conductor 10IRIS I Range of Remote Control 16 PRESENCE SENSOR Detection mode Presence Response time 128ms Technology Focused active infrared and self monitored microprocessor Spot diameter standard 4 max Number of spots 24 or 12 spots by curtain Number of curtains 2 Detection field 7 Ht Width Depth Wide 6...

Страница 3: ...ir may jeopardize personal safety and may expose one to the risk of electrical shock may adversely affect the safe and reliable performance of the product will result in a voided product warranty 2 Mounting the sensor follow the instructions on the enclosed template Mount the sensor at a maximum height of 2 from the bottom line of the door operator Use the mounting template to drill holes and posi...

Страница 4: ...e screw clockwise To tilt the curtain out turn the screw counterclockwise Keep a minimum distance of 2 between the door and the first curtain Use the Spotfinder accessory to locate and adjust the position of the curtains When mounting one sensor on each side of the door above a highly reflective threshold select different frequencies to avoid crosstalk between the sensors 1 Important User Guide Sy...

Страница 5: ... will once again be required unless it is deleted as described below To re lock the sensor without a lock code or with a new lock code perform the following To return to no lock code simply press lock once followed by 0000 3 Remote Control Programming Launch a setup by performing the following Unlock the sensor to enter into adjustment session RED LED Press Unlock key flashes slowly To launch an a...

Страница 6: ...door permanently open red LED ON 3 door permanently closed red LED OFF No monitoring reply Installation Configuration Mounting Height Pulse Frequency SINGLE UNIT 1 Low Low 2 High Low 3 Low High 4 High High OVERLAPPING UNITS 5 Low Low 6 High Low 7 Low High 8 High High Important Note Upon detection at the sensor both relays will be simultaneous triggered Relay 1 is assigned to the white and green ou...

Страница 7: ...ty level is set to Snow Mode a specific trigger is required to enter into the mode If the sensor completes 2 learn cycles within 6 detections it will enter into Snow Mode During this mode the sensor will change the 2 nd infrared curtain the one farthest from the door to IR motion as opposed to IR presence Additionally the automatic learn time will change from whatever it was set to to 10 seconds T...

Страница 8: ...mended to set sensors close to each other with remote control The access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 No code is required to unlock during the first minute after powering To enter a lock code simply press the Lock key followed by a lock code If lock code is less than 4 digits the lock key must be pressed a second time following the last digit of ...

Страница 9: ...f the infrared curtains emitted by the IRIS PN 10WCA WCA This is a ceiling adaptor for use on drop ceilings or otherwise Maximum ceiling thickness allowed is about PN 10WMB WMB This is a 90 degree mounting bracket to allow installation on a flat horizontal surface PN 10URC URC This is a universal rain cover to shield the sensor from direct rain contact 6 Accessories sold individually ...

Страница 10: ...counterclockwise The door is not closing LED OFF On Off switch at door control is in wrong position or is faulty Check to insure that On Off switch for door is in the ON or AUTOMATIC position Improper output configuration on the sensor Check the output configuration setting on each sensor Improper door control configuration Verify that Door Control F2 is set to Normal The presence detection is dis...

Отзывы: