background image

 

75.5351.02  EN   20080317   (75.5350) 

Page 1 of 7 

 

 

 

 

FALCON & FALCON XL 

USER'S GUIDE 

 

MOTION SENSORS FOR INDUSTRIAL DOORS 

• 

FALCON

: for high mounting    

 

FALCON XL

: for low mounting

 

 

Technology:

  Microwave and microprocessor 

Transmitter frequency: 

 

24.125 GHz 

Transmitter radiated power:  

<20 dBm EIRP  

Transmitter power density:

   < 5 mW/cm² 

Mounting height  

 

FALCON: from 11.5 to 23’ 

 

FALCON XL: from 6.5 to 11.5’ 

Tilt angle:

  

0° to 180° in elevation 

Detection zone (typical) 

 

Wide pattern (FALCON XL): 13’ (W) x 6.5’ (D) 

 

for a mounting height of 8.2’ 

 

Narrow pattern (FALCON): 13’ (W) x 16’ (D)  

 

for a mounting height of 16’ 

Detection mode: 

movement 

Minimum detection speed

2.2 in/s (measured in the 
sensor axis) 

Supply voltage: 

12V to 24V AC +/- 10% 

 

12V to 24V DC +30% / -10% 

Mains frequency: 

50 to 60 Hz 

Power consumption

: < 

2W 

Output relay: 

free of potential changeover contact 

 

Max contact voltage : 42V AC/ DC 

 

Max contact current: 1A (resistive) 

 

Max switching power: 30W (DC) / 60 VA (AC)

 

Hold time: 

0.5s to 9s (adjustable)

 

Manual adjustment: 

 orientation of sensing field  (mechanically)  

 multiple functions (by push buttons).

 

Remote control adjustments: 

 

 Sensitivity. 

 

 Hold time. 

 

 Detection mode.  

 

 Pedestrian and parallel traffic rejection mode. 

 

 Relay configuration.

 

Temperature range :

 -22°F to 122°F (-30°C to +60°C) 

Degree of protection:

   IP65  

Product conformity:   
 

R&TTE 1999/5/EC 

 EMC 

89/336/EEC

 

Dimensions :

 5 in (D) x 4 in (W) x 3 ¾ (H) 

 

(127mm (D) x 102 mm (W) x 96mm (H)) 

Weight:

  

0.88 lbs (400 g) 

Housing Material:  

ABS and Polycarbonate 

Bracket Material: 

 

black anodized aluminum 

Cable length: 

33 ft (10 m) 

Cable diameter: 

1/8” (3 mm) (minimum) 

 

1/4” (6.5 mm) (maximum) 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

The sensor must be firmly 
fastened in order not to 
vibrate. 

The sensor must not be 
placed directly behind a 
panel or any kind of 
material. 

The sensor must not 
have any object likely to 
move or vibrate in its 
sensing field. 

The sensor must not 
have any fluorescent 
lighting in its sensing 
field. 

 

DESCRIPTION OF 

THE SENSOR   

 

INSTALLATION 

TIPS

 

 

TECHNICAL  

SPECIFICATIONS 

Содержание Falcon

Страница 1: ... current 1A resistive Max switching power 30W DC 60 VA AC Hold time 0 5s to 9s adjustable Manual adjustment orientation of sensing field mechanically multiple functions by push buttons Remote control adjustments Sensitivity Hold time Detection mode Pedestrian and parallel traffic rejection mode Relay configuration Temperature range 22 F to 122 F 30 C to 60 C Degree of protection IP65 Product confo...

Страница 2: ...housing slot guides Gently push the front cover and make sure that the external housing is properly seated front cover must be flush with housing Screw the 2 front cover screws and tighten the retaining nut Ceiling Mounting Wall Mounting Remark The bold type values give the minimum distance required to be able to fully adjust the sensor Check that both locking collar are at the same angle Align th...

Страница 3: ...following adjustments tilt angle 15 30 45 sensitivity 9 The sensing fields here on the right correspond to the following adjustments tilt angle 30 sensitivity 9 6 3 When the power is turned ON the red and green LEDs flash for few seconds During a detection the red LED lights on During configuration the red LED flashes a number of times corresponding to the parameter being changed see next table Th...

Страница 4: ...to the 0000 value factory setting or during the first minute after the power on press only the UNLOCK Key 3 no code required UNLOCK with code UNLOCK without code 0000 The red LED flashes quickly waiting for the access code After entering the correct code or if no code is required the red LED flashes slowly to indicate that the unlock is successful and the adjustment session has begun NOTE Adjustme...

Страница 5: ...ent session all the parameters may be reset to their factory values in the following way PARAMETER KEY USER S ACTIONS DEFAULT VALUES Press the DEFAULT VALUES Key 12 then press the NUMBER Key 1 All the parameters are reset to the factory values see below DEFAULTS VALUES PARAMETER KEY USER S ACTIONS FACTORY SETTING LED SIGNAL SENSITIVITY Press the SENSITIVITY Key 6 Use the NUMBER Keys 0 9 1 to enter...

Страница 6: ...level to obtain the required rejection 2 Unidirectional Approach 1 No rejection The red LED flashes quickly waiting for the value Once this has been entered it flashes slowly again The red LED flashes quickly waiting for the value Once this has been entered it flashes slowly again Without remote control all of the parameters can be set using the 2 push buttons NOTE These two buttons are accessible...

Страница 7: ... and then release it SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION The door will not open and the red LED does not light up The sensor power is off Check power supply Check the supply voltage The sensor sees the door moving Increase the tilt angle and or reduce the sensitivity The door opens and closes constantly When closing the door creates vibrations picked up by the sensor Ensure that the sensor is...