BEA FALCON DR Скачать руководство пользователя страница 4

75.5268.01 20070111 

 

Page 4 of 7

 

 

1.  DESCRIPTION OF THE INFRARED REMOTE CONTROL 

 

 

 

 Open the battery compartment at the back of the remote control ; 

 Insert two AAA batteries supplied with the remote control as shown beside ; 

 Close the battery compartment.

 

 

 

0-9 Number keys   (1)

Output redirection   (2)

Plus   (3)

Unlock   (4)

Minus   (5)

Holdtime   (6)

Sensitivity   (7)

Detection mode   (8)

Rejection mode   (9)

 

 

 

 

(10) Not used 
(11) Not used 
(12)  Not used  
(13) Not used 
(14) Not used 

(15)  Check Values  
(16) Lock  

(17)  Output configuration  

(18)  Not used  

(19) Setup  

(20) Not used 

 

 

Note: For optimum results point the remote control to the sensor 
before pressing its buttons.  

 

 

2.  CONFIGURATION OF THE SENSOR 

 

Every adjustment session using the infrared remote control must start with unlocking and end with a double locking.  

 

 
The table below lists the parameters able to be adjusted by remote control and the operations required in order to adjust these 
parameters. 

PARAMETERS ACTIONS 

LED SIGNAL 

UNLOCK 

 

 
 
 
 

Press the UNLOCK key (4).  
Enter your 4-digit access code using 0-9 NUMBER keys (1). 

During  the first sensor adjustment or if the access code is reset to the "0000" value 
(factory setting)
 or during the first minute after the power-on, press only the UNLOCK key 
(4) (no access code required). 
 

UNLOCK with access code 

  

 

 

 

 

UNLOCK without access code 

 

 

The red LED flashes quickly waiting for the 
access code. 
 
After entering the correct access code or if no 
access code is required, the red LED flashes 
slowly to indicate that the unlock is successful 
and the adjustment session has begun. 

 

Note:   = Adjustment session ON 

LOCK 

 

 

When all the parameters have been set, press the LOCK key (16). 

If you wish to enter a new access code, use 0-9 NUMBER  
keys (1) to enter the new 4-digit access code within 1 minute. 

If no access code is entered or if you want to keep the current access code, press the 
LOCK key (16) once more.  

If no remote control key is pressed within 1 minute, the adjustment session is automatically 
locked. 
 

LOCK with access code change 

 

 

 

 

  

LOCK without access code or access code change 

 

 

 

The red LED stops flashing to return to its normal 
function. 

 
CONFIGURATION 
WITH REMOTE 
CONTROL 

Содержание FALCON DR

Страница 1: ...witching power 30W DC 60VA AC Hold time 0 5s to 9s adjustable Temperature range 22 F to 122 F 30 C to 60 C Degree of protection IP65 Norm conformity R TTE 1999 5 EC EMC 89 336 EEC Dimensions 4 W x 5 D x 3 H 102 mm W x 127 mm D x 96 mm H Weight 0 88 lbs 0 4 kg Material of housing ABS and polycarbonate Material of bracket Anodized aluminium Length of cable 33 10m Manual adjustment Orientation of sen...

Страница 2: ...ousing Screw the 2 front cover screws and tighten the retaining nut Check that both locking collars are at the same position Align the bracket slot to the locking collar guide as shown BROWN GREEN Power supply YELLOW COM 1 WHITE NC 1 PINK NO 1 BLACK COM 2 RED NC 2 BLUE NO 2 To insert or to remove the cable Unscrew the retaining nut Pass the cable through the retaining nut and the grommet Screw the...

Страница 3: ...ng adjustments Tilt angle 30 Sensitivity 9 6 3 The sensing fields here on the left correspond to the following adjustments Tilt angle 15 30 45 Sensitivity 9 The sensing fields here on the left correspond to the following adjustments Tilt angle 15 30 45 Sensitivity 9 The sensing fields here on the left correspond to the following adjustments Tilt angle 30 Sensitivity 9 6 3 The sensing fields here o...

Страница 4: ...NLOCK key 4 Enter your 4 digit access code using 0 9 NUMBER keys 1 During the first sensor adjustment or if the access code is reset to the 0000 value factory setting or during the first minute after the power on press only the UNLOCK key 4 no access code required UNLOCK with access code UNLOCK without access code The red LED flashes quickly waiting for the access code After entering the correct a...

Страница 5: ...nterferences with the sensor DETECTION MODE Press the DETECTION MODE key 8 Use the NUMBER keys 1 3 1 to select the required mode Key 1 bidirectional mode Key 2 unidirectional mode Key 3 unidirectional mode with the MTF function DETECTION MODE With the bidirectional mode the approaching and departing target is detected With the unidirectional mode only the approaching target is detected Using the M...

Страница 6: ...o the factory values Press and hold both push buttons simultaneously until the two LEDs switch on for 1 second after 2 seconds During the manual adjustment session the red and green LEDs flash successively and continuously The flashing number of the red LED provides the number of the displayed parameter see next table The flashing number of the green LED provides the value of the displayed paramet...

Страница 7: ... on unlock then on lock and introduce a new access code Batteries in the remote control are weak or installed improperly Check the batteries insertion Change the batteries The sensor does not respond to the remote control Remote control is badly pointed Point the remote control towards to the sensor TROUBLE SHOOTING Do not leave problems unresolved If a satisfactory solution cannot be achieved aft...

Отзывы: