BEA FALCON DR Скачать руководство пользователя страница 1

75.5268.01 20070111 

 

Page 1 of 7

 

 

 

FALCON DR  / FALCON XL-DR

 

USER’S GUIDE

 

 

MOTION SENSORS FOR INDUSTRIAL DOORS 

FALCON DR: 

double relay / high mount

  

  FALCON XL-DR: 

double relay / low mount

 

 

Technology                     

:  Microwave and 

microprocessor 

Transmitter frequency    

:  24.125 GHz 

Transmitter radiated power  :  <20 dBm EIRP 

Transmitter power density 

:  < 5 mW/cm² 

Mounting height   

   

 

FALCON DR 

:  from 11.5’ (3.5m) to 23’ (7m)  

 

FALCON XL-DR 

:  from 6.5’ (2m) to 11.5’ (3.5m) 

Tilt angles 

:  0° to 180° in elevation 

Detection zone 

 FALCON DR 

(mounting height of 5m) 

 

13’ (W) x 16’ (D) 

4m (W) x 5m (D) 

 FALCON XL-DR 

(mounting height of 2.5m) 

 

13’ (W) x 6.5’ (D) 

4m (W) x 2m (D) 

Detection mode 

:  Motion 

Minimum speed 

:  2 in (5cm)/s (measured in the 

sensor axis) 

Supply voltage 

:  12V to 24V AC ±10% 

12V to 24V DC +30% / -10% 

Mains frequency 

:  50 to 60 Hz 

Power consumption 

:  < 2W (VA) 

Two Output relay (free of potential change-over contact) 

 

Max. contact voltage 

:  42V AC 

 

Max. contact current 

:  1A (resistive) 

 

Max. switching power 

:  30W (DC) / 60VA (AC) 

 

Hold time 

0.5s to 9s (adjustable) 

Temperature range 

-22°F to +122°F (-30°C to +60°C) 

Degree of protection 

IP65 

Norm conformity 

R&TTE 1999/5/EC 

EMC 89/336/EEC 

Dimensions : 

4” (W) x 5” (D) x 3 ¾” (H) 

 

  102 mm (W) x 127 mm (D) x 96 mm (H) 

Weight : 

0.88 lbs (0.4 kg) 

Material of housing 

ABS and polycarbonate 

Material of bracket 

Anodized aluminium 

Length of cable 

33’ (10m) 

Manual adjustment 

   

 

Orientation of sensing field  (mechanically) 

 

Multiple functions (by push buttons) 

Remote control adjustments 

 

Sensitivity 

 

Hold time 

 

Detection mode 

 

Pedestrian and parallel traffic rejection mode 

 

Output configuration 

 

Security 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

 
 
 
 

 

 

 
 
 
 
 
 

 

 

 

The sensor must be firmly 
fastened to prevent from 
vibrating.

 

The sensor must not be placed 
directly behind a panel or any kind 
of material.

 

The sensor must not have 
any object likely to move or 
vibrate in its sensing field.

 

The sensor must not have any 
fluorescent lighting in its 
sensing field. 

 
DESCRIPTION OF 
THE SENSOR   

 
INSTALLATION 
TIPS

  

 

 
TECHNICAL 
SPECIFICATION 

Tranceiver module 

(planar antenna) 

 

Green LED 

 

Infrared Receiver 

 

Red LED 

 

 

 

 

 

2 Push Buttons 

 

 

Microprocessor 

 

 

Terminal block 

Содержание FALCON DR

Страница 1: ...witching power 30W DC 60VA AC Hold time 0 5s to 9s adjustable Temperature range 22 F to 122 F 30 C to 60 C Degree of protection IP65 Norm conformity R TTE 1999 5 EC EMC 89 336 EEC Dimensions 4 W x 5 D x 3 H 102 mm W x 127 mm D x 96 mm H Weight 0 88 lbs 0 4 kg Material of housing ABS and polycarbonate Material of bracket Anodized aluminium Length of cable 33 10m Manual adjustment Orientation of sen...

Страница 2: ...ousing Screw the 2 front cover screws and tighten the retaining nut Check that both locking collars are at the same position Align the bracket slot to the locking collar guide as shown BROWN GREEN Power supply YELLOW COM 1 WHITE NC 1 PINK NO 1 BLACK COM 2 RED NC 2 BLUE NO 2 To insert or to remove the cable Unscrew the retaining nut Pass the cable through the retaining nut and the grommet Screw the...

Страница 3: ...ng adjustments Tilt angle 30 Sensitivity 9 6 3 The sensing fields here on the left correspond to the following adjustments Tilt angle 15 30 45 Sensitivity 9 The sensing fields here on the left correspond to the following adjustments Tilt angle 15 30 45 Sensitivity 9 The sensing fields here on the left correspond to the following adjustments Tilt angle 30 Sensitivity 9 6 3 The sensing fields here o...

Страница 4: ...NLOCK key 4 Enter your 4 digit access code using 0 9 NUMBER keys 1 During the first sensor adjustment or if the access code is reset to the 0000 value factory setting or during the first minute after the power on press only the UNLOCK key 4 no access code required UNLOCK with access code UNLOCK without access code The red LED flashes quickly waiting for the access code After entering the correct a...

Страница 5: ...nterferences with the sensor DETECTION MODE Press the DETECTION MODE key 8 Use the NUMBER keys 1 3 1 to select the required mode Key 1 bidirectional mode Key 2 unidirectional mode Key 3 unidirectional mode with the MTF function DETECTION MODE With the bidirectional mode the approaching and departing target is detected With the unidirectional mode only the approaching target is detected Using the M...

Страница 6: ...o the factory values Press and hold both push buttons simultaneously until the two LEDs switch on for 1 second after 2 seconds During the manual adjustment session the red and green LEDs flash successively and continuously The flashing number of the red LED provides the number of the displayed parameter see next table The flashing number of the green LED provides the value of the displayed paramet...

Страница 7: ... on unlock then on lock and introduce a new access code Batteries in the remote control are weak or installed improperly Check the batteries insertion Change the batteries The sensor does not respond to the remote control Remote control is badly pointed Point the remote control towards to the sensor TROUBLE SHOOTING Do not leave problems unresolved If a satisfactory solution cannot be achieved aft...

Отзывы: