Note: 

    

All parameters or functions listed in the following tables are only accessible if the sensor is in adjustment session.  

 

The red LED is then slowly flashing. 

 

During an adjustment session each parameter may be checked or changed at any time in the following way :

 

PARAMETERS 

 OPERATIONS 

CHECK 
VALUES 

 

Press the key corresponding to the parameter to be checked and then press the 

CHECK VALUES 

key (15). 

Count the number of times the LED flashes, which corresponds to the value of the checked parameter. No LED flash corresponds to the 
value 0. 
Repeat this operation to check the value of the other parameters if required. 
Example : 

SENSITIVITY

 key (7)  – 7 flashes of the LED : the radar sensitivity is set at the value 7. 

CHECK VALUES

 :   

 

 

    

PLUS 

 

Press the key corresponding to the sensitivity (7) or holdtime (6) parameter to be modified and then press the 

PLUS 

key (3) to increase the 

value by 1 unit.

 

PLUS

 : 

 

 

 

MINUS 

 

Press the key corresponding to the sensitivity (7) or holdtime (6) parameter to be modified and then press the 

MINUS 

key (5) to reduce the 

value by 1 unit.

 

MINUS

 :  

 

 

 

 

 

Note about LED signal: The red LED flashes quickly waiting for the value. Once this has been entered, it flashes slowly again.

 

PARAMETERS 

OPERATIONS 

DEFINITIONS - ADVICES 

SENSITIVITY 

 

Press the 

SENSITIVITY 

key (7). 

Use the 

NUMBER 

keys 

0-9 

(1) to enter the required sensitivity (or adjust this 

parameter using the 

PLUS 

(3) or 

MINUS 

(5) keys as explained above) 

SENSITIVITY :

   

 

  

 

 

To increase the 

sensitivity 

means to increase the sensor 

capabilities to detect small useful signals.  
Practically, to increase the sensitivity leads to increase the 
dimensions of the sensing field. 

HOLD TIME 

 

 

Press the 

HOLD TIME 

key (6). 

Use the 

NUMBER 

keys 

0-9

 (1) to enter the required hold time (0.5 s to 9 s)  

(or adjust this parameter using the 

PLUS 

(3) or 

MINUS 

(5) keys as explained 

above). 

HOLD TIME 

:  

 

 

 

 

The 

hold time

 allows extended output activation time after a 

motion detection has stopped. It is recommended to use this 
parameter instead of the operator’s one with the same function 
(interferences with the sensor) 

DETECTION 
MODE 

 

 

EAGLE ONE HM 
only!

 

Press the 

DETECTION MODE 

key (8). 

Use the 

NUMBER 

keys 

1-5

 (1) to select the required mode : 

Key 1 

: Bidirectional mode 

Key 2

 : Unidirectional mode 

Key 3

 : Unidirectional mode with MTF-function 

Key 4

 : Unidirectional mode reverse 

Key 5

 : Unidirectional mode reverse with MTF- function 

 

DETECTION MODE : 

 

 

 

 

With the 

bidirectional mode

, the approaching and departing 

target is detected. With the 

unidirectional

 mode, only the 

approaching

 target is detected. With the 

unidirectional

 mode 

reverse

, only the 

departing

 target is detected. 

  
Using the 

MTF (Motion Tracking Feature)

 enables the sensor 

to automatically switch from the unidirectional mode to 
bidirectional mode as soon as a target is detected. This 
function is recommended for applications with elderly people 
or anyone approaching the door hesitantly. 

 

IMMUNITY 

 

Press the 

IMMUNITY 

key (9).

 

Use the 

NUMBER 

keys 

1-9 

(1) to select the 

required mode:

 

Key 1

:     Detection of quasi-presence 

Key 2

:     Normal 

Key 3

:     Increased immunity 

Key 4-9

:  Additional increased immunities 

4: lowest level  
9: highest level 

IMMUNITY :

    

                                                      

   

 

 

To 

increase the immunity

 means to strengthen the 

resistance to external disturbances such as 

rain, vibrations

etc. 
 
The 

additional increased immunity

 modes (4-9) reduce 

disturbances in highly reflective environments (

airlocks, 

curved and round sliding doors, metallic environments 
etc

.). 

MOUNTING 
HEIGHT 

  

Press the 

MOUNTING HEIGHT 

key (13),  

Use the 

NUMBER 

keys 

1-2 

(1) to select the required mounting height : 

Key 1 

: Standard mounting height 

Key

 

2

 : High mounting height 

MOUNTING HEIGHT

:  

    

   

 

 

The sensor presents an increased sensitivity scale in 

high 

mounting mode

. This setting is recommended when the 

detection on the field limits is erratic. 

OUTPUT 
CONFIGURA-
TION 

 

Press the 

OUTPUT CONFIGURATION

 key (17). 

Use the NUMBER keys 

1-2

 (1) to select the required output configuration : 

Key 1

 : Active mode 

Key 2

 : Passive mode 

OUTPUT CONFIGURATION

:  

   

 

 

 

 

Active 

Passive 

Detection 

 

 

No Detection 

 

 

 

DOOR 
CONTROL 

 

  

Press the 

DOOR CONTROL

 key (14),  

Use the NUMBER keys 

1-3

 (1) to select the required door control: 

Key 1

 : Automatic mode  

Key 2

 : Door permanently open 

Key 3

 : Door permanently closed 

DOOR CONTROL:

  

 

 

 

In ‘’door permanently open’’ mode, the sensor is continuously 
detecting. The red LED is continuously ON. 
 
In ‘’door permanently closed’’ mode, the sensor is in standby. 
It detects nothing anymore and the LED is continuously OFF. 

Содержание EAGLE ONE HM

Страница 1: ... 215 kg Material ABS Color of housing anthracite gray aluminum finish or white Length of cable 2 5m Manual adjustment Sensitivity by push buttons Orientation of sensing field mechanically Remote control adjustments Sensitivity Hold time Detection mode Immunity Mounting height Output configuration Door control Security 10 levels from 0 5s to 9s in 10 levels uni bidirectional MTF reverse mode Eagle ...

Страница 2: ...ock 12 24V AC DC COM NO NC This device may be fixed on the ceiling as long as the spherical part of the sensor is facing in the direction opposite the door and as long as an angular position of around 70 is chosen for the antenna For the mounting on the upper part of the door operator profile use the EBA support For a mounting into the ceiling use the ECA embedding support For a better water tight...

Страница 3: ...GLE OF THE ANTENNA The sensing fields here on the right correspond to the following adjustments Sensitivity 9 Bidirectional mode Mounting height 5m To obtain a sensing field as close to the door as possible set the antenna at its minimum tilt angle 0 to 15 Example of deep field operator application To obtain a sensing field close to the door set the antenna at a tilt angle of 30 Example of standar...

Страница 4: ...e access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 During the first sensor adjustment or if the access code is reset to the 0000 value factory setting or during the first minute after the power on press only the UNLOCK key 4 no access code required UNLOCK with access code of 4 digits UNLOCK with access code of less than 4 digits UNLOCK without access code The...

Страница 5: ... MODE key 8 Use the NUMBER keys 1 5 1 to select the required mode Key 1 Bidirectional mode Key 2 Unidirectional mode Key 3 Unidirectional mode with MTF function Key 4 Unidirectional mode reverse Key 5 Unidirectional mode reverse with MTF function DETECTION MODE With the bidirectional mode the approaching and departing target is detected With the unidirectional mode only the approaching target is d...

Страница 6: ...or control is set to level 3 Check the wiring and the power supply Set door control to automatic mode level 1 The sensor sees the door moving Increase the tilt angle and or reduce the sensitivity and or increase the immunity The door opens and closes constantly When closing the door creates vibrations picked up by the sensor Ensure that the sensor is correctly fixed Switch to unidirectional mode I...

Страница 7: ...ck during the first minute after powering Press on unlock then on lock and introduce a new access code Batteries in the remote control are weak or installed improperly Check the batteries insertion Change the batteries The sensor does not respond to the remote control Remote control badly pointed Point the remote control towards the sensor TROUBLE SHOOTING ...

Страница 8: ...ion of conformity and other technical documentation are available on our website or can be requested by phone or mail BEA S A LIEGE Science Park Allée des Noisetiers 5 B 4031 Angleur Tel 3243616565 Fax 3243612858 info bea be www bea be ...

Отзывы: