BEA Eagle HM Скачать руководство пользователя страница 4

75.1038 V3 Jun 2005 [Rev. June 10, 2005]    

          

                                                                                                                                                    

  Page 4 of 8 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 
 
 

 
 
 

 
 

 

 
 
 
 
 
 

 

C. 

THE LATERAL POSITION OF THE SENSING FIELD IN FRONT OF THE DOOR IS DETERMINED BY THE LATERAL 
TILT ANGLE OF THE ANTENNA.

 

 
 
 

The sensing fields on the right 
correspond to the  
following adjustments : 

 

 lateral angle of the  

       antenna : 15°, -15° ; 

 

 sensitivity : 6 (middle), 

       9 (max.) 

 

 Mounting height : 16’ 

 

20° Angle 
 
 
 
 
 
 
 
 
 

 
D. 

THE DIMENSIONS  (WIDTH, DEPTH_OF THE SENSING FIELD DEPEND ON THE SENSITIVITY SETTING.

 

 

The sensing fields on the right correspond to the  
following adjustments : 

 

 vertical angle of the  

       antenna : 20° 

 

 Mounting height :16’ 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

MECHANICAL 
ADJUSTMENTS - 

SETTING THE 
SENSING FIELD 
DIMENSIONS – 
Cont.  

 

 

3.2’ 

 

 

6.4’ 

 

9.6’

70º

 

For

 ceiling 

mounting, the vertical tilt angle 

of the antenna must be set at the maximum 
position of 

70-75°

 and the spherical part of 

the sensor must be oriented in the opposite 
direction to the door.

 

+15º 

-15º 

6.4’     3.2’      0       3.2’    6.4’

 6.4’      3.2’      0        3.2’      6.4’

 

 
3.2 
 
6.4 
 
9.6’ 
 
12.8’ 
 
16’ 

S=6 

S=9

Содержание Eagle HM

Страница 1: ...nsor must not have any object likely to move or vibrate in its sensing field The sensor must not have any fluorescent lighting in its sensing field Frequency 24 125 GHz Supply voltage 12 to 24 V AC 10 12 to 24 V DC 10 30 Mounting height 16 5 feet Tilt angle 0 to 90 vertical 30 to 30 lateral Detection area 13 1 ft x 8 2 ft Minimum detection speed 2in sec measured in axis Power consumption 2 W Stand...

Страница 2: ...compliance with all applicable safety standards upon completion of installation From behind before installation From the front after installation Paste the template at desired location Drill as instructed Insert screws but do not screw them fully in If possible pass the cable where it is supposed to go through If you don t want to drill your profile for the cable you can cut the wire opening footp...

Страница 3: ...r To obtain a sensing field close to the door the tilt angle of the antenna must be set at the position 20 Example of use with a normal operator Shown in Picture B above To obtain a sensing field far from the door the tilt angle of the antenna must be set at the maximum position 27 Example of use with a normal operator Shown in picture C above SENSING FIELDS ACCORDING TO THE VERTICAL TILT ANGLE OF...

Страница 4: ...NS WIDTH DEPTH_OF THE SENSING FIELD DEPEND ON THE SENSITIVITY SETTING The sensing fields on the right correspond to the following adjustments vertical angle of the antenna 20 Mounting height 16 MECHANICAL ADJUSTMENTS SETTING THE SENSING FIELD DIMENSIONS Cont 0 3 2 6 4 9 6 70º For ceiling mounting the vertical tilt angle of the antenna must be set at the maximum position of 70 75 and the spherical ...

Страница 5: ...lities perform as follows BI DIRECTIONAL MODE Detection of all motion towards or away from the sensor UNI DIRECTIONAL MODE The detector will work in a uni directional mode at all times regardless of traffic patterns detecting only motion moving toward the sensor OR UNI DIRECTIONAL MODE WITH MTF The principle is as follows The detector does NOT activate its relay as long as it detects movement excl...

Страница 6: ... STATUS Press the function key that you desire to inquire about followed by pressing the CHECK VALUES key After pressing INQUIRY count the number of LED flashes this corresponds to the setting EXAMPLE After pressing a function button the red LED flashes quickly After pressing the CHECK VALUES key the LED flashes the number of the current setting No LED flash will indicate a setting of 0 7 Default ...

Страница 7: ...tantly 1 Increase the tilt angle of the antenna 2 Reduce sensitivity DETECTION MODE 3 Detection mode offers 3 different levels of detection Bi directional Uni directional and Uni directional with MTF motion tracking feature MTF allows the Eagle to switch from uni directional to bi directional upon detection from the normal approach direction After pressing the DETECTION MODE key the red LED flashe...

Страница 8: ...545 Mid West 1 888 308 8843 West Coast 1 888 419 2564 DO NOT leave any problem unresolved If you must wait for the following workday to call B E A leave the door inoperable until satisfactory repairs can be made NEVER sacrifice the safe operation of the automatic door or gate for an incomplete solution Web www beasensors com OTHER ACCESSORIES PN 10ECA For mounting into the ceiling use the ECA embe...

Отзывы: