UNIVERSAL OPTIONS
Lock
Note: Not used on DK-12
Unlock
Note: Not used on DK-12
Inquiry
?
For any product application specified
herein, compliance to the ANSI A1
56.10-2005 standard is strictly
performance driven. Therefore,
following each installation and/or
adjustment, it is necessary to
properly walk-test and document
the performance of all sensors to
ultimately help aide in the
determination of compliance.
Testing and final determination of
ANSI compliance should be
performed by inspectors that have
been certified by the American
Association of Automatic Door
Manufacturers (AAADM).
DISCLAIMER
* Active output (Fail-Secure):
NC-COM circuit is closed and
NO-COM circuit is open.
** Passive output (Fail-Safe):
NO-COM circuit is closed and
NC-COM circuit is open.
75.0180.05 20080915
BODYGUARD
Sensitivity (0-9)
Default = 6 Closed, 7 Open
Hold Time (0-9)
0 (0.5 sec.) to 9 (9.0 sec.)
Relay Output (1-2)
1. NO Relay* 2. NC Relay**
Auto Learn Time (0-9)
0 - 30 sec 4 - 5 min 8 - 10 sec
1 - 1 min 5 - 7 min 9 - Infinity
2 - 2 min 6 - 10 min (no learn)
3 - 3 min 7 - 15 min
Pattern Width (1-9)
1. Wide (Door Closed)
2. Middle (Door Open)
3. Asymmetrical Left Narrow
4. Asymmetrical Right Narrow
5. Narrow Left
6. Narrow Right
7. Asymmetrical Left Wide
8. Asymmetrical Right Wide
9. Center Narrow
Pattern Depth (1-6)
1. Deep - Threshold On
2. Medium - Threshold On (Open)
3. Limited - Threshold On
4. Deep - Threshold Off
5. Medium - Threshold (Closed)
6. Limited - Threshold Off
Immunity (1-3)
1. Low 2. Medium 3. High
Set-Up (1-2 or 9)
1. Door Closed 2. Door Open
9. Restore Factory Defaults
Infrared Frequency (1-4)
1. Normal/Low 3. Quiet/Low
2. Normal/High 4. Quiet/ High
DK-12
Pattern Width (1-6)
1. Wide
(open & closed)
4. Left Narrow
2. Left Wide 5. Center Narrow
3. Right Wide 6. Right Narrow
Frequency (1-2)
1. High Impulse 2. Low impulse
Relay Output (1-4)
1. Passive Output** 3. ON
2. Active Output* 4. OFF
Sensitivity (0-9)
Default = 8 Closed, 7 Open
Set-Up (1-2 or 9)
1. Door Closed 2. Door Open
9. Restore Factory Defaults
F2
Door Control (1-3)
1. Normal (LED Normal Mode)
2. Door Permanently Open (On)
3. Door Permanently Closed (Off)
BodyGuard & DK12 differences only