BEA CONDOR ID Скачать руководство пользователя страница 7

7/8

microwave and infrared

24.175 GHz

2

<< 5mW/cm

< 20 dBm EIRP

motion and presence

green, red

12 - 24V AC +10% / -10%

12 - 24V DC +10% / - 3%

50 - 60 Hz

< 3.5W

2 relays with switch-over contact (free of potential)

60V DC / 125V AC

1A (resistive) @ 24V DC

30W (DC) / 60VA (AC)

2.5m - 3.2m

0° to 45°

-8° to +15° (relative to sensor front face)

-30°C to +60°C

IP65

Electromagnetic compatibility (EMC) according to 

ABS + PC

black

7.5m

2004/108/EEC

127 mm (D) x 102 mm (B) x 96 mm (H)

400g

Technology:

Radiated frequency:

Radiated power density:

Transmitter radiated power:

Detection mode:

LED-signal:

Supply voltage:

(measured at cable end)

Mains frequency:

Power consumption:

Output:

Max. voltage:

Max. current:

Max. switching power:

Installation height:

Tilt angle sensor:

Tilt angle radar:

Temperature range:

Protection degree:

Norm conformity:

Dimensions:

Weight:

Material:

Colour:

Cable length:

Specifications are subject to change without prior notice.

TECHNICAL SPECIFICATIONS

Содержание CONDOR ID

Страница 1: ...STOP SIGNAL P 4 P 3 At the end of the installation or after changing the adjustment of the sensor it is MANDATORY to introduce the preset value in function of the installation height by remote control...

Страница 2: ...ing objects in the detection field Avoid HF neon and discharge lamps in the detection field LED FLASHES QUICKLY LED FLASHES SLOWLY SETUP STOP SIGNAL LED OFF Fixing screw Radar antenna Infrared lenses...

Страница 3: ...llets is selected the radar detection field is slightly smaller 12 24V GND COM NO COM NO NC NC GREEN BROWN WHITE YELLOW PINK VIOLET GREY BLACK POWER SUPPLY START SIGNAL STOP SIGNAL NOT USED NOT USED D...

Страница 4: ...ttings Standard Standard Vestibule Vestibule REMOTE CONTROL PRESETTINGS When 2 or more sensors are installed close to each other or their detection fields overlap alternate the frequencies between sen...

Страница 5: ...1 min 2 min 5 min 10 min 20 min 1 h 1 30 h 2 h passive active passive active unlock lock value check frequency 1 frequency 2 setup presettings factory settings 0 9 1 or 4 Relay configuration Size of...

Страница 6: ...ion of the lamps Point the remote control towards the sensor Check the power supply of the sensor The sensor does not unlock even after entering the access code You have to enter a code or the wrong c...

Страница 7: ...according to ABS PC black 7 5m 2004 108 EEC 127 mm D x 102 mm B x 96 mm H 400g Technology Radiated frequency Radiated power density Transmitter radiated power Detection mode LED signal Supply voltage...

Страница 8: ...SENSORIO A division of BEA SA LIEGE Science Park All e des Noisetiers 5 4031 Angleur B T 32 4 361 65 89 F 32 4 361 28 58 info sensorio be www sensorio be 8 8 42 0627 V8 03 10...

Отзывы: