«click»
max.
5 cm
max 5 cm
12-24 V
AC-DC
ACTIV8 THREE F
0
1
2
1
2
0
1
2
3
3
3
9
1
H
W
H
W
2 m
1 m
MOUNTING & WIRING
RADAR FIELD - OPENING IMPULSE
INFRARED FIELD - SAFETY
GREEN
BROWN
YELLOW
WHITE
PINK
GREY
RED*
BLUE*
POWER SUPPLY
MONITORED
OPENING INPUT
OPENS DOOR
SAFETY INPUT
KEEPS DOOR OPEN
TEST
OUTPUT
2.2 m
WIDTH
ANGLE
4 m x 2 m
2 m x 2.5 m
Check position of
IR-curtains with
Spotfi nder and
adjust if necessary.
WIDTH
ANGLE
TIP
:
Launch an
ASSISTED SETUP
to verify wiring, position of the curtains and correct functioning of the sensor.
It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.
DOOR
ORANGE
GREEN
LED
RED
LED
* For compliance with DIN 18650, connection
to door controller test output is required.
2.2 m
Max. mounting height: 3 m
Max. mounting height: 4 m
(>3 m excludes DIN18650-conformity)
CLOSER
CLOSER
AWAY
AWAY
2.2 m
The door control unit and the door cover profi le must be correctly earthed.
S
E
NS
OR
Detection fi eld width indicated according to conditions defi ned in DIN 18650 and including dimension of test body CA.
H
W
2.20 m 2.35 m
2.50 m 2.50 m
3.00 m 2.70 m
The width of the radar fi eld varies according to the mounting height of the sensor.
H
W
2.20 m 1.35 m
2.50 m 1.50 m
3.00 m 1.70 m
>
>
>
>
>
1
2
4
A
P
0
1
2
1
2
0
1
2
3
3
3
+
0
1
2
1
2
0
1
2
3
3
3
-
XXS
XS
S
>
>
>
>
L
XL
XXL
XXS
, XS
, S ...
...
L
,
XL
,
XXL
>
ACTIV8 THREE F
>
1
5
>
+
>
>
>
>
SETTINGS
(by push buttons and/or remote
control)
SHORT PUSH RIGHT:
+ 1 VALUE
SHORT PUSH LEFT:
- 1 VALUE
RADAR FIELD SIZE
(SENSITIVITY)
excludes DIN18650-conformity of the door system
FIELD SIZE
(SENSITIVITY)
IMMUNITY FILTER
DETECTION MODE
HOLD TIME
OUTPUT SIGNAL
NUMBER OF
CURTAINS
IMMUNITY FILTER*
MAX. PRESENCE
TIME
PULSE FREQUENCY
TEST
(MONITORING)
OUTPUT
CONFIGURATION
service mode = no detection is active during 15 minutes (maintenance).
dynamic mode = 2
nd
curtain is only active during motion detection.
auto = the sensor will automatically adapt to the door controller:
when the door controller monitors the sensor > on
when the door controller does not monitor the sensor > off
(excludes DIN18650-conformity)
L= 3.20 m x 1.40 m
(at 2.2 m)
A = active output (NO-contact)
P = passive output (NC-contact)
bi
uni
dynamic
mode
service
mode
on
auto
off
FACTORY VALUES
low
30
s
1
min
2
min
5
min
10
min
20
min
60
min
freq A
freq A+
freq B+
normal
0.5 s
1 s
2 s
3 s
4 s
5 s
6 s
7 s
8 s
9 s
high
normal
Safety
motion
OUTPUT
REDIRECTION
motion
or
presence
opening output is active in case of: 0 motion detection
1 motion
or
presence detection
OR
RED-GREEN
PUSH
LEFT + RIGHT
bi = two-way detection; uni = one-way detection towards sensor;
uni PRM = for persons with reduced mobility
uni
PRM
QUICK SETUP =
ASSISTED SETUP =
SETUP
(step out of the detection fi eld during setup)
PUSH RIGHT UNTIL
OPEN+CLOSE
RED-GREEN
OFF
RED-GREEN
FLASHES
OR
RESETTING TO
FACTORY VALUES
RED-GREEN
OFF
IMPORTANT
:
Test the good functioning of the installation before leaving the premises.
medium
high
* In immunity 2 and 3, the standard detection capability is the same as in immunity 1 (factory setting). Environmental and installation conditions can
affect the detection capability of the sensor or can impact the availability of the door system. During harsh conditions, the sensor can temporarily
adapt the detection capability to ensure the availability of the door system.
immunity 3 is only suitable if a combined
sensor is on each side of the door
freq B
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery
directive 2006/42/EC.
Only trained and qualifi ed personnel may install and setup the sensor.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Avoid touching any electronic and optical components.