BEA hereby declares that the ACTIV8 THREE F is in conformity with the basic requirements and the other
relevant provisions of the directives 1999/5/EC, 2004/108/EC and 2006/42/EC.
Notifi ed Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
Angleur, November 2010
Jean-Pierre Valkenberg, Authorized representative
The complete declaration of conformity is available on our website: www.bea.be
LED-SIGNALS
The ORANGE LED
fl ashes 1 x.
The ORANGE LED
fl ashes 2 x.
The ORANGE LED
fl ashes 4 x.
The ORANGE LED
fl ashes 5 x.
The ORANGE LED
fl ashes every second.
The ORANGE LED
is on.
The RED LED fl ashes
quickly after an
assisted setup.
The RED LED
lights up
sporadically.
The GREEN LED
lights up
sporadically.
The LED is off.
The reaction of
the door does not
correspond to the
LED-signal.
The sensor goes into
security mode.
The sensor signals
an internal fault.
Irregularities in the
power supply
The sensor receives
not enough IR-energy.
The sensor receives
too much IR-energy.
The sensor encounters
a memory problem.
The sensor vibrates.
The sensor sees the door
during the assisted setup.
The sensor sees the door.
The sensor is disturbed by
lamps or another sensor.
The sensor is disturbed
by the rain.
The sensor is disturbed by
rain and/or leaves.
The sensor vibrates.
Ghosting
The sensor sees the door
or other moving objects.
Check power supply.
Check wiring.
Use the 1 m prism if possible.
Check the angle of the IR-curtains.
Cut and restore power supply.
Cut and restore power supply.
If orange LED lights up again, replace sensor.
Check the angle of the IR-curtains.
Launch a new assisted setup.
Attention: Do not stand in the detection fi eld!
Check output confi guration setting.
Switch value 1 (P) to 2 (A) or 2 to 1 by remote
control.
Use a low energy prism if possible.
Check the angle of the IR-curtains.
Check if the sensor is fastened fi rmly.
Check position of prism and cover.
Choose a different frequency by remote control.
Increase the IR-immunity fi lter to value 2 or 3.
Increase radar-immunity fi lter by remote control.
Change radar antenna angle.
Check if the sensor is fastened fi rmly.
Check position of cable and cover.
Change radar antenna.
Change radar fi eld size (sensitivity).
Remove the objects if possible.
Launch an assisted setup and adjust the IR angle.
Cut and restore power supply.
If orange LED fl ashes again, replace sensor.
*excludes DIN18650-conformity of the door system
Check connections to test output.
If your door controller is not able to test the sensor,
connect the red and blue cable to power supply.*
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
The ORANGE LED
fl ashes 6 x.
The ORANGE LED
fl ashes 7 x.
The radar sensor output is
faulty.
The radar sensor encounters
a hardware problem.
Replace sensor.
The sensor is disturbed.
Replace sensor.
Change radar antenna angle.
ACTIV8 THREE F
3
2
4
1
5
6
7
E
R
L
A
U
B
T
Z
E
R
T I
F I
Z I E R U N G
N
A
C
H
DIN 1
865
0
E
N
A
B L
E S
A C C
O
R
D
A
N
C
E
W
I
T
H
TECHNICAL SPECIFICATIONS
1. IR-prism
(2 m)
2. radar
antenna
(wide fi eld)
3. radar
antenna
(narrow fi eld)
4. cover
DESCRIPTION
Presence
Typical response time: <128 ms (max. 500 ms)
Typical: < 15 ms (max. 25 ms)
Active infrared with background analysis
Spot diameter: 0.1 m (typ)
Number of spots: 24 or 12 by curtain
Number of curtains: 2
From -4 ° to +4 ° (adjustable)
0.3 s to 1 s (not adjustable)
Transistor (optocoupled transistor)
Max. output current: 100 mA
Max. switching power: 42 V DC
ENGLISH
Opening & safety sensor
for automatic sliding doors
in escape routes
5. push
buttons
6.
IR-curtain ajustment screw
7. main
connector
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%
(to be operated from SELV compatible power supplies only)
< 3 W
1.8 m to 4 m
(< 3 m to enable DIN 18650-conformity)
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C
IP54
5 years
R&TTE 1999/5/EC; EMC 2004/108/EC; MD 2006/42/EC; EN 12978
EN ISO 13849-1:2008 Performance Level «d» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
Supply voltage:
Power consumption:
Mounting height:
Sensitivity of the test input:
Temperature range:
Degree of protection:
Expected lifetime:
Norm conformity:
Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm2
From 15 ° to 50 ° vertical (adjustable)
0.5 s to 9 s (adjustable)
Transistor (optocoupled transistor)
Max. output current: 100 mA
Max. switching power: 42 V DC
State “motion detection”:
output signal not pulsed
State “no motion detection”:
output signal pulsed (f = 100 Hz +/-10%)
Detection mode:
Response time on test request:
Technology:
Angle:
Hold time output signal:
Output:
GREEN
LED
RED
LED
All values measured in optimal conditions.
Other use of the device is outside the permitted purpose
and can not be guaranteed by the manufacturer. The
manufacturer cannot be held responsible for incorrect
installations or inappropriate adjustments of the sensor.
Please keep for further use
Designed for colour printing
For pr
oduct version 0700 and mor
e