active infrared

presence detection by distance measurement

35mm x 70mm (at 2.2m mounting height)

64ms

0.6m - 3m

12V - 24V AC/DC -5% / + 10%

50 - 60 Hz

120mA @ 24V AC / 80mA @ 24V DC

relay (free of potential contact)

42V AC/DC

1A (resistive)

30W (DC) / 60VA (AC)

0.5s

min. 10% at IR-wavelength of 850nm

-25°C - +55°C; 0-95% rel. humidity, non condensing

IP53

Electromagnetic compatibility (EMC) according to 

144mm (L) x 40mm (H) x 50mm (D)

ABS (black)

2.5m

2004/108/EC

Technology:

Detection mode:

Detection field:

Response time:

Mounting height:

Supply voltage:

Mains frequency:

Max. current consumption:

Standard output:

Max. contact voltage:

Max. contact current:

Max. switching power:

Hold time:

Reflectivity:

Temperature range:

Degree of protection:

Norm conformity:

Dimensions:

Housing material:

Length of main cable:

Specifications are subject to changes without prior notice

42.0608 - V3 / 01.13

TROUBLESHOOTING

RED

OFF

RED

RED

4x

 ORANGE

Launch setup and check adjustment.

Bad adjustment of the uncovered zone.

The monitoring mode is wrong. 

Launch a manual setup.

Change the position of DIP 4.

Check wiring: connect RED and 
BLUE to monitoring output.
If the door control has no monitoring:
do not connect RED and BLUE wires.

Launch a manual setup.

Launch a manual setup.

Launch a new setup.

The signal received from background
 is too weak.

The distance to the floor has changed 
due to external factors.

The sensors interfere with each other
due to overlapping detection zones.

You are standing inside the detection field.

Step outside the detection field.

Check if the sensor is installed 
correctly.

Range is too short.

The signal received from background is
too weak.

Increase the distance between the 
sensors or select a different 
frequency on each sensor.

Check if proximate modules have 
different frequencies.

Increase the uncovered zone.

The sensor detects
eratically.

The red LED is
permanently ON.

The LED is OFF, 
but the relay “clicks”.

The red LED 
flickers.

The orange LED 
flashes 4x 
during setup.

The red LED 
flashes 
during setup.

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

TECHNICAL SPECIFICATIONS

The wiring is not correct.

1 optocoupler 

(free of potential contact)

30V

High state: >10V

Low state: <1V

Monitoring input:

Max. contact voltage:

Voltage threshold: