3   Precautions

Shut off all power before attempting any wiring procedures.

Maintain a clean & safe environment when working in public areas.

Constantly be aware of pedestrian traffic around the door area.

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.

ESD:  Circuit boards are vulnerable to damage by electrostatic discharge.  Before handling any board ensure you dissipate your body’s charge.

Always check placement of all wiring before powering up to insure that moving door parts will not catch any wires and cause damage to equipment.

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10 / A156.19) upon completion of installation.

DO NOT attempt any internal repair of the sensor. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disas-
sembly or repair:

1.  May jeopardize personal safety and may expose one to the risk of electrical shock.

2.  May adversely affect the safe and reliable performance of the product will result in a voided product warranty.

1   Description

The MATRIX (10MATRIX) Digital Inductive Loop Detector is the ideal solution for parking barrier control, motorized gates and doors, vehicle 
access control and industrial control systems.  The MATRIX is a high performance single or dual-channel vehicle detector packaged in a 

compact housing.  The connection is made with a standard industrial 11-pin round connector.  The six versions listed below include single or 

dual-channel, and 3 possible power supplies:

10MATRIXS110   : Single loop detector with 110 to 120 V AC power supply.
10MATRIXS220   : Single loop detector with 220 to 240 V AC power supply.
10MATRIXS1224 : Single loop detector with 12 to 24 V AC/DC power supply.
10MATRIXD110   : Dual loop detector with 110 to 120 V AC power supply.
10MATRIXD220   : Dual loop detector with 220 to 240 V AC power supply.
10MATRIXD1224 : Dual loop detector with 12 to 24 V AC/DC power supply.

“The Peak Of Detection” 

Power LED

Dip Switches

Detection State LED

Presence Time

  Adjustment

Potentiometer

Sensitivity Adjustment

        Potentiometer

      (Dual Loop Only)

Detection State LED

   (Dual Loop Only)

Sensitivity Adjustment

        Potentiometer

2   Specifications

TERMINOLOGY

SPECIFICATION

TERMINOLOGY

SPECIFICATION

TECHNOLOGY

Inductive Loop

POWER FREQUENCY

48 to 62 Hz

TUNING

Automatic

POWER CONSUMPTION

< 2.5 W

DETECTION MODE

Presence

TEMPERATURE RANGE

-22ºF to 158ºF (-30ºC to 70ºC)

PRESENCE TIME

1 min to infinity with 250 steps

DEGREE OF PROTECTION

IP40

PULSE TIME OUTPUT

100 ms or 500 ms

WEIGHT

7 oz. (<200g)

LED INDICATORS

Power:  Green
Loop Status 1:  Red
Loops Status 2:  Red

PROTECTIONS

Loop Insulation Transformer
Zener Diodes
Gas Discharge Clamping

FREQUENCY RANGE

20 kHz to 130 kHz

INDUCTANCE RANGE

20 H to 1000 H

FREQUENCY STEPS

Single Loop:  4
Double Loop:  2 (for each loop)

DIMENSIONS

3.0 in (H) x 1.5 in (W) x 3.0 in (D)

(76mm x 38mm x 76mm)

SENSITIVITY (ΔL / L)

0.005% to 0.5% with 250 steps

CONNECTION

86CP11 (Standard 11-Pin Round)

REACTION TIME

Single Loop:  25ms  
Double Loop: 50ms (ea. channel)

2 OUTPUT RELAYS (free po-
tential change-over contact)

Max Contact Voltage:  230 VAC

Max Contact Current:  5A (res.)

SETUP TIME AFTER CONFIGURATION

2 s max by channel

SETUP TIME AT POWER ON

8 s max by channel

POWER SUPPLY
(depending on model)

12-24 AC/DC + 10%
230 VAC  + 10%
115 VAC + 10%

PRODUCT COMPLIANCE

R&TTE:  1999/5/EC
EMC:  89/336/EEC
FCC:  47 CFR 15
IC:  RSS-210 ISSUE 5

FCC ID#: G9B-MATRIX     IC ID#: 4680A-MATRIX

Содержание 10MATRIX

Страница 1: ...s 10MATRIXS110 Single loop detector with 110 to 120 V AC power supply 10MATRIXS220 Single loop detector with 220 to 240 V AC power supply 10MATRIXS1224 Single loop detector with 12 to 24 V AC DC power supply 10MATRIXD110 Dual loop detector with 110 to 120 V AC power supply 10MATRIXD220 Dual loop detector with 220 to 240 V AC power supply 10MATRIXD1224 Dual loop detector with 12 to 24 V AC DC power...

Страница 2: ...end only The feeder cable must be firmly fixed to avoid any false detection max length 330 ft 100m Waterproof cable junction box is required B LOOP GEOMETRY When two adjacent loops are connected to a dual channel sensor it is possible for these loops to share a common slot if so required As the channels are multiplexed no interference will occur Avoid large loops or long feeder max 330 ft 100 m or...

Страница 3: ... Configuration B Dual loop in independent mode Configuration C Dual loop in combined mode Dip Switch OFF ON OFF ON OFF ON DS 1 High loop A Low loop A High 30 High loop A Low loop A High 30 DS 2 See next table High loop B Low loop B High 30 High loop B Low loop B High 30 DS 3 Active mode Passive mode Active mode Passive mode Active mode Passive mode DS 4 ASB OFF ASB ON ASB OFF ASB ON ASB OFF ASB ON...

Страница 4: ...takes place according to dip switches 7 and 8 WARNING DURING THE DETECTION THE 2 LOOPS HAVE TO DETECT SIMULTANEOUSLY FOR A SHORT PERIOD TO BE ABLE TO DETERMINE THE MOVEMENT DIRECTION DURING LOOP INSTALLATION MAKE SURE THE 2 LOOPS ARE CLOSE ENOUGH TO EACH OTHER TO ENSURE A COMMON DETECTION TYPICAL 3 FEET 7 Relay B Function Presence or Pulse or Loop Selection for Relay B Pulse Pulse on Loop B or Pul...

Страница 5: ...frequency too HIGH LED blinking faster at 2 Hz Loop shorted or no oscillation LED blinking slower at 0 5 Hz 10 Troubleshooting 11 Company Contact Do not leave problems unresolved If a satisfactory solution cannot be achieved after troubleshooting a problem please call BEA Inc If you must wait for the following workday to call BEA leave the door inoperable until satisfactory repairs can be made Nev...

Страница 6: ......

Страница 7: ...o doble con alimentación eléctrica de 12 a 24 VCA CC The Peak Of Detection 2 Especificaciones TERMINOLOGÍA ESPECIFICAIONES TERMINOLOGÍA ESPECIFICAIONES Tecnología Circuito Inductivo Frecuencia de energía 48 to 62 Hz Sintonización Automática Consumo de energía 2 5 W Modo de detección Presencia Rango de temperaturas 22ºF to 158ºF 30ºC to 70ºC Tiempo de presencia 1 minuto a infinito presencia permane...

Страница 8: ... falsa longitud máx 330 pies 100 m Se requiere una caja de conexiones de cables impermeable B GEOMETRÍA DEL CIRCUITO Cuando se conectan dos circuitos adyacentes a un sensor de doble canal es posible que estos circuitos compartan una ranura en común en caso de ser necesario Como los canales están multiplexados no se puede producir ninguna interferencia Evite el uso de circuitos largos o cables alim...

Страница 9: ... 0 25 0 18 0 10 0 005 SENSIBILIDAD MÁX MIN Configuración A Circuito simple Configuración B Circuito doble en modo independiente Configuración C Interruptor Dip OFF ON OFF ON OFF ON INT DIP 1 Alto circuito A Baja circuito A Alto 30 INT DIP 2 Consulte la siguiente table Alto circuito B Baja circuito B Alta circuito B Alto 30 INT DIP 3 INT DIP 4 ASB OFF ASB ON ASB OFF ASB ON ASB OFF ASB ON INT DIP 5 ...

Страница 10: ...N LOS 2 CIRCUITOS DEBEN DETECTAR SIMULTÁNEAMENTE DURANTE UN PERÍODO CORTO PARA PODER DETERMINAR LA DIRECCIÓN DEL MOVIMIENTO DURANTE LA INSTALACIÓN DEL CIRCUITO COMPRUEBE QUE LOS 2 CIRCUITOS ESTÉN SUFICIENTEMENTE CERCA EL UNO DEL OTRO PARA ASEGURAR UNA DETECCIÓN COMÚN TÍPICAMENTE 0 90 M 7 Función del relé B presencia o impulso O bien Selección del circuito para el impulso del relé B Impulso en el c...

Страница 11: ...ación LED parpadea a menos de 0 5 Hz 10 Solución de Problemas 11 Información de contacto de la empresa No deje problemas sin resolver Si no encuentra una solución satisfactoria tras consultar la sección de solución de problemas llame a BEA Inc Si debe esperar al día hábil siguiente para llamar a BEA deje la puerta clausurada hasta que se puedan hacer las reparaciones necesarias Nunca sacrifique la...

Страница 12: ......

Отзывы: