Appendix B - Door Controls
75.5652.01
20100830
Page
15
of
16
DP-Hub Wire Color
Green
Yellow
White
Green/
Black
Yellow/
Black
White/
Black
Green/
Red
Yellow/
Red
White/
Red
Door Control
ACT
NO
ACT
NC
ACT
COM
SAFE
NO
SAFE
NC
SAFE
COM
STALL
NO
STALL
NC
STALL
COM
Besam 300
13
12
11
12
15
16
Besam MP/CUP
3
4
9
4
5
4
Besam SM900/CU2
1
3
2
3
5
3
Door O Matic
Yellow
Grey
Blue
Grey
Purple
Grey
Dorma 400/700
TRIG
GND
PRES
GND
SWING
GND
Gyrotech 300/400
Black
Red
White
Red
White
Red
Gyrotech MAG
6 Black
5 Red
4 White
5 Red
3 Violet
5 Red
Horton 4190
2
3
4
3
10
3
Hunter
ACT
RTN
SAF 1
RTN
SAF 2
RTN
Keane Monroe K
Green
White
Red
White
Yellow
White
Record 6000/8000
2
1
8
4
10
11
Stanley L
Orange
Yellow
Red
Yellow
Blue
Yellow
Stanley MP
2
8
7
8
7
8
Stanley 521
TB4-4
TB4-3
TB3-8
TB4-3
TB3-4
TB3-3
Appendix C - Home Switch
1
Retro Fit or Precision Install
In some cases it may be necessary to adjust the Home Switch for a retro
fi
t application where the Door Mounted Sensor Extrusions were
previously installed and are not close to the ideal mounting location of approximately 1” apart, or if you just want to make the install
as precise as possible.
If the extrusions are too close, the Home Switch will open too late and it’s possible that the BodyGuard may still see the
door(s) on a manual push or stack pressure before the switch opens, thus causing safety. Conversely if the extrusions are too far apart,
the Home Switch may not close at door closed.
To precisely adjust the Home Switch you have two options. First you can use the Home Switch LED (orange) on the DP-Hub. To use the
Home Switch LED the DP-Hub must be powered, the magnetic reed switch must be wired into the EDPS and the EDPS must be plugged into the
DP-Hub. Alternatively if you have a multimeter with continuity, all you will need to do is remove the magnetic reed switch wires from the EDPS and
connect them to your meter with it set to continuity.
1. Loosen the set screw from the Home Switch collar and pull out or push in the magnetic reed switch in the collar so that it corrects your Home
Switch problem. If the extrusions are less than 1” apart, you will need to pull out the magnetic reed switch from the collar. Conversely if you the
extrusions are greater than 1” you will have to push in the magnetic reed switch into the collar. Note that the absolute maximum range of the
magnetic reed switch is 1 1/2”, thus if you are further than that apart you will have to re-install the extrusions or select an alternative solution as
described in the next section.
2. Check the Home Switch precision using either the Home Switch LED or your meter. You want the switch to be closed when the door(s) is
closed, but you want to switch to open within a few degrees when the door(s) are off of your desired home. Repeat until your desired location
is found. A simple way to perform this with the meter is to pull the switch out until you lose continuity, the push it back in slightly.
3. Tighten the set screw on the Home Switch collar and jump back to the previous installation step.
Home
Switch LED
(orange)
Home Switch Default
Home Switch Extended
NOTE: If your door control is not shown above please refer to appropriate installation manual as this system will work on any door.