background image

Page 2 of 2 

 

75.0092 V4 Jan 2004 [Rev. 1/26/2004] 

COMPANY 
CONTACT 

 

MECHANICAL 
INSTALLATION  

 

 

1. 

Prepare the box for installation.  If the pushplate is to be hard-wired to the operator, remove either the 
knockout on the back or bottom of the box.  Then route the appropriate wire to the box. 

2. 

Attach the box to the mounting surface.  For surface mounted boxes, securely attach the box to the 
surface using the corner holes.  For flush mounted boxes, cut a hole in the mounting surface large enough 
that the galvanized steel bracket will pass through the hole.  Then use a Phillips head screwdriver to 
tighten the two screws that tighten the bracket to the inside of the wall surface. 

 

 

GALVANIZED MOUNTING 

BRACKET

 

SURFACE MOUNT 

FLUSH MOUNT 

 
3. 

If applicable, mount a radio frequency transmitter to the inside of the housing using either the transmitter 
pins and 9V battery clip, or the Velcro tab enclosed with the transmitter kit. 

 

 

10BOX45RSM with 10T300PB shown 

9V Battery 

Transmitter Mounting Pins

 

(adjust location for transmitter) 
or use Velcro tab to secure 
‘mini’ transmitters 

 

 

 

 

If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call B.E.A., Inc. 
for further assistance during 

Eastern Standard Time at 1-800-523-2462 from 8am - 5pm.  

For after-hours, call East Coast: 1-866-836-1863 or 1-800-407-4545 / Mid-West: 1-888-308-8843 /  
West Coast: 1-888-419-2564.

 DO NOT leave any problem unresolved

. If you must wait for the following 

workday to call B.E.A., leave the door inoperable until satisfactory repairs can be made.  

NEVER sacrifice the safe operation of the automatic door or gate for an incomplete solution. 