•  Attempt to carry out the measurements regularly at the same time of day, since 

blood pressure changes during the course of the day. The ideal time to measure 

your blood pressure is in the morning after you wake up, before breakfast and 

physical activity, and in the absence of the urge to urinate.

•  Rest  for  5  minutes  sitting  quietly  and  release  all  the  tension  in  your  body 

especially the arm muscles before beginning with the measurement. Remain 

calm and quiet when the measurement is in process. Do not speak or move 

your arm (as well as other body) muscles during the process.

•  With repeated measurements, blood accumulates in the arm, which can lead 

to false results. Consecutive blood pressure measurements should be repeated 

after at least a 15 second pause or after the arm has been held up in order to 

allow the accumulated blood to flow away.

•  Do not lean backward or bend your wrist inward while taking a measurement.

4.2B Fitting the Wrist

a) Remove all accessories (watch, bracelet, etc.) from your left wrist. If your 

physician has diagnosed you with poor circulation in your left arm, use your 
right wrist.

Содержание RX803

Страница 1: ...AUTOMATIC WRIST Blood Pressure Monitor Instruction manual...

Страница 2: ......

Страница 3: ...nts 1 Introduction 1 1 Features 1 2 Important Information 1 2A Safety Information 2 About Blood Pressure 2 1 Normal Blood Pressure Values 2 2 Common Blood Pressure Questions and Answers 3 Getting Star...

Страница 4: ...g the Wrist 4 2C Choose your Measurement Position 4 3 Measuring Your Blood Pressure 4 4 Automatic Inflation 4 5 Discontinuing a Measurement 5 Viewing Previously Recorded Measurements 5 1 Clearing All...

Страница 5: ...enient and easy operation this device provides a simple yet accurate method to measure your blood pressure Your blood pressure is an important parameter that can be used to monitor your health This de...

Страница 6: ...by extension and contraction of the artery of the wrist in response to each heartbeat The amplitude of the pressure waves is measured converted to millimeters of the mercury column and is shown on the...

Страница 7: ...values must always be discussed with your doctor or a physician who is familiar with your family history If you are undergoing medical treatment and receiving medication consult your doctor to determ...

Страница 8: ...in your blood pressure and thus treat you accordingly Morning Hypertension 135 85 mmHg Recently several studies have identified elevated cardiovascular risks heart failure stroke angina associated wi...

Страница 9: ...batteries in the device Incorrect usage may cause battery fluid leakage To prevent such accidents refer to the following instructions Insert batteries with the correct polarity Turn off power after us...

Страница 10: ...ulse or heart rate and the width of blood vessels through changes in muscles in the walls of blood vessels Your blood pressure reading is highest when your heart pumps or ejects blood This stage is ca...

Страница 11: ...rt brain muscles can be the result Furthermore with long term increased blood pressure values the heart will become structurally damaged There are many different causes of the appearance of high blood...

Страница 12: ...kidney and your heart Should the systolic blood pressure values lie between 140 mmHg and 160 mmHg or the diastolic blood pressure values lie between 90 mmHg and 95 mmHg consult your doctor Regular sel...

Страница 13: ...s units mmHg according to the World Health Organization WHO Category Systolic Blood Pressure Diastolic Blood Pressure Optimal 120 80 Normal 130 85 High Normal 130 139 85 89 Hypertension Stage 1 Mild S...

Страница 14: ...Correctly measured diastolic blood pressure values above 120 mmHg require immediate medical treatment 2 2 Common Blood Pressure Questions and Answers a Why is my blood pressure reading always differe...

Страница 15: ...AM Time PM mmHg...

Страница 16: ...excited nervous or tense while taking a bath during and after exercise or strenuous physical activity when it is cold within one hour after meals after drinking tea coffee or other caffeinated drinks...

Страница 17: ...it is possible for blood pressure to increase due to anxiety and tension c Why should I monitor blood pressure at home One or two readings will not provide a true indication of your normal blood press...

Страница 18: ...3 Getting Started 3 1 About the Device 1 2 3 4 5 1 LCD 2 Battery compartment 3 Wrist cuff 4 On Off button 5 Memory button 6 Batteries 7 Case...

Страница 19: ...your heart rate It also displays previously recorded measurements and the date and time when the appropriate button is pressed 1 Time Date 2 Systolic Blood Pressure mmHg 3 Diastolic Blood Pressure mmH...

Страница 20: ...partment cover NOTE Replace the batteries whenever the weak battery icon shows the display is dim or the display does not illuminate when the power is on Replace all the batteries at the same time it...

Страница 21: ...1 Setting Date and Time 1 When the device is turned on for the first time the display will show as Fig 1 2 Press and hold the M button then press the O I button the year number flashes as Fig 2 3 Pres...

Страница 22: ...r blood pressure and pulse rate 4 2A Before Measuring Avoid eating smoking as well as all forms of exertion directly before the measurement All these factors influence the measurement result Relax by...

Страница 23: ...nd quiet when the measurement is in process Do not speak or move your arm as well as other body muscles during the process With repeated measurements blood accumulates in the arm which can lead to fal...

Страница 24: ...of your palm e Fasten the wrist cuff around your wrist leaving no extra room between the cuff and your skin If the cuff is too loose the measurement will not be accurate 4 2C Choose your Measurement P...

Страница 25: ......

Страница 26: ...surement relax for 5 minutes Don t talk or move your arm 2 Press the O I button and all symbols will appear on the display for 2 seconds as Fig 4 Then 0 will appear on the screen The pump begins to in...

Страница 27: ...en levels of inflation pressure for this device 190 mmHg 230 mmHg 270 mmHg and 300 mmHg When 190mmHg is not enough or movement of wrist occurs the device will automatically inflate to a reasonable pre...

Страница 28: ...st reading will be replaced by the new one Memory will not clear away even if power supply is removed 2 After a measurement is finished or when the device is in standby mode press the M button to reca...

Страница 29: ...Continue to press the M button to view all stored measurements 5 1 Clearing All Values After a measurement is finished or when the device is in standby mode press and hold down the M button for at le...

Страница 30: ...Health Organization WHO as shown in the chart to the right The indicator displays a segment based on the current data corresponding to the WHO classification For example if your blood pressure is 135...

Страница 31: ...eartbeat Detector This device provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs When the device detects an irregular heartbeat or any excessive body movement...

Страница 32: ...not inflated to necessary pressure Make sure that cuff is put on correctly and repeat measurement Repeat the measurement with no movement and follow recommendations in the manual Repeat the measuremen...

Страница 33: ...ft and dry cloths to clean the device 5 Since neither the device nor batteries are household waste follow your local recycling rules and dispose of them at appropriate collection sites 6 Do not open t...

Страница 34: ...ttery contact is not being made Replace all batteries with new ones Install batteries correctly Clean the battery terminals with dry cloth Inflation stops and re inflates later The automatic inflation...

Страница 35: ...ct Wrap the cuff correctly Relax during measurement Keep quiet and still during measurement Pulse rate is too low or too high Did you talk or move your arm hand during measurement Did you take a measu...

Страница 36: ...is warranted for two years The warranty does not cover damage from misuse or tampering If you have questions regarding the operation of your monitor call the Blood Pressure Hotline 1 866 536 2289 Shou...

Страница 37: ...orkmanship Please allow 10 days for repair and return shipping 12 Technical Specifications Size 2 75 H x 2 3 W x 1 2 D Weight 110g Storage Temperature 20 C to 50 C 4 F to 122 F Storage Humidity 85 and...

Страница 38: ...Accuracy Pressure 3 mmHg Pulse 5 Memory Maximum 90 Cuff circumference 12 5 to 20 5 cm 4 9 to 8 inches Power Source 2 x AAA 1 5V batteries...