BDITEST.COM
QUICK START
GUIDE
For the complete S100 manual go to:
https://bditest.com/S100-Manual
Страница 1: ...BDITEST COM QUICK START GUIDE For the complete S100 manual go to https bditest com S100 Manual ...
Страница 2: ...ceptacle on the panel Twist the barrel of the connector to secure it 3 Use either cable with the magnetic clamp or the mechanical clamp Connect clamp to bare clean steel To activate the magnetic clamp place it on a bare clean steel surface then turn the switch to ON 4 Insert the battery pack into the handle in the orientation shown in the drawing below until the pack snaps into place Charge the ba...
Страница 3: ... firm hand tight S100 Stinger Spot Bonder Bonding Handle and 5 ft Cables 1x Straight Bonding Tip Magnetic Grounding Clamp With 5 ft Cable Mechanical Grounding Clamp With 5 ft Cable 1x Milwaukee M12 REDLITHIUM 3 0 Battery Milwaukee M12 Lithium Ion Battery Charger M12 and REDLITHIUM are registered trademarks to the Milwaukee Electric Tool Corporation ...
Страница 4: ...TROL CABLE 2 LI ION BATTERY BUTTON 6 POSITIVE ELECTRODE LEAD 3 BOND INTENSITY CONTROLS 7 GROUND TERMINAL 4 DISPLAY ERROR CAUSE SOLUTION bA Lo Very low battery Check battery charge level Change to battery with full charge If ambient temperature is cold make sure the battery itself is warm rE Resistance error Bonding resistance greater than 1 ohm Ensure all connections are properly made and tight Ch...