S2528PB Hardware Installation Manual

- 12 -

Figure 3- 5 Cable connection at the console port

3.3.2 Connecting Gigabit Ethernet SFP Ports

The S2528PB switch has 4 gigabit SFP ports. Each port has a corresponding

indicator for showing their LINK/ACT state. If the indicator is always on, the port is

normally linked; if the indicator flickers, the data is forwarded through the port. In

use the SFP optical module can be connected to the SFP optical module and

connected to other Ethernet terminal devices through the optical cable.

Figure 3-6 Gigabit SFP ports connect to other Ethernet terminal devices

3.3.3 Connecting 1000M Ethernet TX Ports

S2528PB provides 24 10/100/1000Base-T ports. Each port corresponds to one

LINK/ACT indicator and POE indicator. In use, the ports can connect other Ethernet

terminal devices through the UTP port and the direct-through or cross network

cable. The numbering order of the pins in the UTP port is the same as the console

port. See the following figure:

Содержание S2528PB

Страница 1: ...S2528PB Hardware Installation Manual...

Страница 2: ...rking 6 2 2 4 Electrostatic Discharge Damage Prevention 7 2 3 Requirements for Common Locations 7 2 3 1 Environment 7 2 3 2 Location Configuration Prevention 7 2 3 3 Cabinet Configuration 7 2 3 4 Powe...

Страница 3: ...14 Chapter 4 Maintaining Switch 15 4 1 Opening the Machine Box 15 4 2 Closing the Machine Box 16 Chapter 5 Hardware Fault Analysis 18 5 1 Fault Separation 18 5 1 1 Faults Relative with Power and Cooli...

Страница 4: ...auto identification UTP RJ45 port Gigabit Ethernet optical port Optical port 100 1000M SFP port Link Act indicators Console port A rate of 9600bps RJ45 interface Table 1 1 Attributes of the built in...

Страница 5: ...Forwards the 10 100M 1000M Ethernet electric signals and provides with POE functions 6 4 SFP ports Forwards 1000M Ethernet optical signals Table 1 2 Parts at the front template of the S2528PB switch...

Страница 6: ...Plus IP routing protocol standard RFC 1058 RIP RFC 1723 RIP v2 Network management standard RFC 1157 SNMP v1 v2 RFC 1213 MIB II RFC 1757 RMON 1 2 3 9 Memory Flash Memory 16M Bytes SDRAM 128M Bytes Stan...

Страница 7: ...S2528PB Hardware Installation Manual 4 1 3 ROHS Description...

Страница 8: ...or dial the power line keep the power line horizontal with the power socket 2 When the lifetime of our products ends handle them according to national laws and regulations or send these products to o...

Страница 9: ...n the machine box or working beside the power source When the power is on do not touch the power Correctly connect the device and the power socket Only professionals are allowed to operate and maintai...

Страница 10: ...mportant for normal system s function Short distance between devices bad ventilation and untouchable control plate will cause maintenance problems systematic faulty and breakdown For location planning...

Страница 11: ...ut side of the switch is reliable The voltage control can be installed if necessary At least a 240 V 10A fuse or a breaker is provided in the phase line if you prepare the short circuit prevention mea...

Страница 12: ...S2528PB 3 2 Installing the Machine Box of the Switch The installation of the machine box has two modes Installing the machine box on the desk Installing the machine box on the cabinet 3 2 1 Installin...

Страница 13: ...witch of S2528PB has a console port The rate of the console port is a value ranging from 1200bps to 115200bps It has a standard RJ45 plug After you connect the console port to the serial port of PC th...

Страница 14: ...port traffic control Therefore you must set the option data traffic control to none when you configure the switch with the super terminal Otherwise the single pass problem will arise on the super term...

Страница 15: ...ptical module can be connected to the SFP optical module and connected to other Ethernet terminal devices through the optical cable Figure 3 6 Gigabit SFP ports connect to other Ethernet terminal devi...

Страница 16: ...the normal phase of the data TXD1 Output 2 Sending the paraphase of the data TXD1 Output 3 Receiving the normal phase of the data RXD1 Input 4 Sending the normal phase of the data TXD2 Output 5 Sendi...

Страница 17: ...hether the installation point between the cabinet and the switch is strong If the switch is installed on the desk check whether there is enough space for the switch to discharge its heat and whether t...

Страница 18: ...scribes how to open the cover of the switch required tools and operation methods Caution When the power cable still connects the power supply do not touch it When you open the cover the switch you may...

Страница 19: ...After taking off the cover put it horizontally and avoid it to be crushed or collided Otherwise the machine box is hard to install 4 2 Closing the Machine Box The section mainly describes how to put...

Страница 20: ...e cover and the bottom are closely tied let the cover slide the slot of the front template at the bottom 3 Nail the bolt and screw it tightly with the screwdriver 4 Reinstall the switch on the cabinet...

Страница 21: ...e fan The working temperature of the switch is from 0 to 40 Celsius degrees If the switch is too hot check whether the air outlet and air inlet are clean and then do relative operations in section 2 3...

Страница 22: ...Switch Indicator Copyright Claims Without the written approval of the company any person or group cannot transcribe copy or change partial or all contents of this manual and must not broadcast it in a...

Отзывы: