Englisch
www.bdsensors.com
DE EN
Montageanleitung /
Mounting instructions
Klemmengehäuse /
Terminal Box
KL 1, KL 2
Zentrale
Headquarters
BD SENSORS GmbH
BD-Sensors-Str. 1
D - 95199 Thierstein
Deutschland /
Germany
Tel.: +49 (0) 92 35 / 98 11-0
Fax: +49 (0) 92 35 / 98 11-11
Osteuropa /
Eastern Europe
BD SENSORS s.r.o.
Hradištská 817
CZ - 687 08 Buchlovice
Tschechische Republik /
Czech Republic
Tel.: +42 (0) 5 72 / 4 11-0 11
Fax: +42 (0) 5 72 / 4 11-4 97
Russland /
Russia
BD SENSORS RUS
39a, Varshavskoe shosse
RU - Moscow 117105
Russland /
Russia
Tel.: +7 (0) 9 59 81 / 09 63
Fax: +7 (0) 9 57 95 / 07 21
Diese Montageanleitung stellt einen Auszug
aus der ausführlichen Betriebsanleitung dar.
Bitte laden Sie sich diese auf unserer Home-
page herunter, falls Sie nicht mit dem Produkt
vertraut sind.
These mounting instructions are an excerpt from the complete
operating manual. It may be downloaded from our homepage, if
you are not familiar with the device.
http://www.bdsensors.de
http://www.bdsensors.com
– Technische Änderungen vorbehalten –
– Technical modifications reserved –
WARNING! In order to avoid hazards to operators and
damages to the device, the following instructions have to
be performed by qualified technical personnel.
WARNING! Adhere to the safety and operating instructions
stated in the operation manual. Effective regulations on o
cupational safety, accident prevention as well as national
installation standards and approved engineering tec
niques must in addition be complied with.
Limitation of liability
If the instructions in the operating manual are not adhered
to or if the device is inappropriately used, modified or da
aged, liability is not assumed and warranty claims will be
excluded.
Intended use
Ensure that the medium is compatible with the media
wetted parts and that the device is suitable for the applic
tion without restrictions. The technical data listed in the cu
rent data sheet is binding.
Product identification
Wiring diagrams
KL 1
KL 2
For the electrical connection a shielded and twisted
multicore cable is recommended
The ground wires of all components have to be connected
when installing!
The supply V
S
has to be chosen according to needs of the
used transmitter.
Type
designation
Ordering code
optional für KL 2 /
optionally for KL 2
:
KL 1
HART
®
Interface
supply
supply
KL 2
with
HART
®
WARNING! In order to avoid hazards to operators and
damages to the device, the following instructions have to
ified technical personnel.
WARNING! Adhere to the safety and operating instructions
stated in the operation manual. Effective regulations on oc-
cupational safety, accident prevention as well as national
installation standards and approved engineering tech-
ques must in addition be complied with.
If the instructions in the operating manual are not adhered
to or if the device is inappropriately used, modified or dam-
aged, liability is not assumed and warranty claims will be
Ensure that the medium is compatible with the media-
wetted parts and that the device is suitable for the applica-
tion without restrictions. The technical data listed in the cur-
rent data sheet is binding.
For the electrical connection a shielded and twisted
multicore cable is recommended.
The ground wires of all components have to be connected
has to be chosen according to needs of the
Mounting
Pin configuration
Designation
(from left)
Terminal block
Electrical connection
(cable colours of BD SENSORS
transmitters)
GND
SENSOR
ground clamp (gn/ye, green
VS-
SENSOR
supply
VS+
SENSOR
GND
SUPPLY
ground clamp
VS+
SUPPLY
VS-
SUPPLY
supply
IN+
TRANSMITTER
(
IN-
TRANSMITTER
supply
GND
TRANSMITTER
ground clamp (gn/ye, green
IN+
SUPPLY
IN-
SUPPLY
supply
GND
SUPPLY
ground clamp
HART
HART (optional)
For more information, please read the detailed operating manual
Serial-
Ordering code
number
height of
housing: 58 mm.
PC
RS 232 C
supply -
V
S
WARNING!
Install the device only in currentless state!
KL 1
mounting hole
ground
4 mm²
cable gland
M16x1.5
(cable
Ø
5 ... 10 mm)
pressure
balance item
housing depth
58 mm.
MA_KL_160118
Electrical connection
(cable colours of BD SENSORS
transmitters)
to connected with
KL 1
gn/ye, green / yellow)
cable shield of transmitter
- (bn, brown)
negative connecting cable of transmitter
(wh, white)
positive connecting cable of transmitter
ground clamp
cable shield of supply line
positive signal line for pressure signal
supply -
negative signal line for pressure signal
KL 2
(wh, white)
positive connecting cable of transmitter
- (bn, brown)
negative connecting cable of transmitter
gn/ye, green / yellow)
cable shield of transmitter
positive signal line for pressure signal
supply -
negative signal line for pressure signal
ground clamp
cable shield of supply line and solid wire (with
overvoltage protection)
-
HART
-modem
For more information, please read the detailed operating manual!
housing: 58 mm.
height of
housing: 55 mm.
KL 2
hole
housing depth
58 mm.
housing depth
55 mm.
cable gland
M16x1.5
(cable
Ø
5 ... 10 mm)
pressure
balance item
mounting hole
∅
4,2
HA_
ON
HART