BD Sensors KL 1 Скачать руководство пользователя страница 2

 

 

Englisch 

www.bdsensors.com 

DE  EN 

 

 
 
 
Montageanleitung / 

Mounting instructions

 

Klemmengehäuse /

 Terminal Box

 

KL 1, KL 2 

  Zentrale  

Headquarters 

 

BD SENSORS GmbH 
BD-Sensors-Str. 1 
D - 95199 Thierstein 

Deutschland / 

Germany

 

Tel.: +49 (0) 92 35 / 98 11-0 

Fax: +49 (0) 92 35 / 98 11-11 

Osteuropa / 

Eastern Europe 

BD SENSORS s.r.o. 
Hradištská 817 
CZ - 687 08 Buchlovice 
Tschechische Republik / 

Czech Republic

 

Tel.: +42 (0) 5 72 / 4 11-0 11 
Fax: +42 (0) 5 72 / 4 11-4 97 

Russland /  

Russia

 

BD SENSORS RUS 
39a, Varshavskoe shosse 
RU - Moscow 117105 
Russland /  

Russia

 

Tel.: +7 (0) 9 59 81 / 09 63 
Fax: +7 (0) 9 57 95 / 07 21 

Diese  Montageanleitung  stellt  einen  Auszug 
aus  der  ausführlichen  Betriebsanleitung  dar. 
Bitte laden  Sie  sich  diese  auf  unserer  Home-
page herunter, falls Sie nicht mit dem Produkt 
vertraut sind.  

These  mounting  instructions  are  an  excerpt  from  the  complete 
operating manual. It may be downloaded from our homepage, if 
you are not familiar with the device. 

http://www.bdsensors.de  

http://www.bdsensors.com  

– Technische Änderungen vorbehalten – 

– Technical modifications reserved – 

 

 

WARNING!  In  order  to  avoid  hazards  to  operators  and 
damages  to  the  device,  the  following  instructions  have  to 
be performed by qualified technical personnel.

 

WARNING! Adhere to the safety and operating instructions 
stated in the operation manual. Effective regulations on o
cupational  safety,  accident  prevention  as  well  as  national 
installation  standards  and  approved  engineering  tec
niques must in addition be complied with.

Limitation of liability 

If the instructions in the operating manual are not adhered 
to or if the device is inappropriately used, modified or da
aged,  liability  is  not  assumed  and  warranty  claims  will  be 
excluded. 

Intended use 

Ensure  that  the  medium  is  compatible  with  the  media
wetted parts and that the device is suitable for the applic
tion without restrictions. The technical data listed in the cu
rent data sheet is binding.

Product identification 

Wiring diagrams 

 KL 1 

KL 2

 

 

For  the  electrical  connection  a  shielded  and  twisted 

multicore cable is recommended

 

The ground wires of all components have to be connected 

when installing! 

 

The supply V

S

 has to be chosen according to needs of the 

used transmitter. 

 

 

Type 

  designation 

Ordering code

 

optional für KL 2 / 

optionally for KL 2

:

KL 1

 

HART

®

 

Interface 

 

supply

supply 

KL 2 

with 

HART

®

 

WARNING!  In  order  to  avoid  hazards  to  operators  and 
damages  to  the  device,  the  following  instructions  have  to 

ified technical personnel. 

WARNING! Adhere to the safety and operating instructions 
stated in the operation manual. Effective regulations on oc-
cupational  safety,  accident  prevention  as  well  as  national 
installation  standards  and  approved  engineering  tech-

ques must in addition be complied with. 

If the instructions in the operating manual are not adhered 
to or if the device is inappropriately used, modified or dam-
aged,  liability  is  not  assumed  and  warranty  claims  will  be 

Ensure  that  the  medium  is  compatible  with  the  media-
wetted parts and that the device is suitable for the applica-
tion without restrictions. The technical data listed in the cur-
rent data sheet is binding. 

For  the  electrical  connection  a  shielded  and  twisted 

multicore cable is recommended. 
The ground wires of all components have to be connected 

has to be chosen according to needs of the 

Mounting

 

Pin configuration 

Designation 

(from left) 

Terminal block 

Electrical connection 

(cable colours of BD SENSORS 

transmitters)

GND 

SENSOR 

ground clamp (gn/ye, green

VS- 

SENSOR 

supply 

VS+ 

SENSOR

 

 

GND 

SUPPLY

 

ground clamp

VS+ 

SUPPLY 

VS- 

SUPPLY 

supply 

IN+ 

TRANSMITTER 

 (

IN- 

TRANSMITTER 

supply 

GND 

TRANSMITTER 

ground clamp (gn/ye, green

IN+ 

SUPPLY 

IN- 

SUPPLY 

supply 

GND 

SUPPLY 

ground clamp

HART 

HART (optional) 

 

 

For more information, please read the detailed operating manual

 

Serial- 

Ordering code 

number 

height of  
housing: 58 mm.

PC 

RS 232 C 

 

supply - 

 

V

S

 

 

 

WARNING!

 

Install the device only in currentless state! 

 

KL 1

 

mounting hole

ground 
4 mm² 

cable gland  

M16x1.5 

(cable 

Ø

5 ... 10 mm) 

pressure 

balance item 

housing depth

58 mm.

MA_KL_160118 

Electrical connection  

(cable colours of BD SENSORS  

transmitters) 

to connected with 

KL 1 

gn/ye, green / yellow) 

cable shield of transmitter 

- (bn, brown) 

negative connecting cable of transmitter 

 (wh, white) 

positive connecting cable of transmitter 

ground clamp

 

cable shield of supply line 

 

positive signal line for pressure signal 

supply - 

negative signal line for pressure signal 

KL 2 

 (wh, white) 

positive connecting cable of transmitter 

- (bn, brown) 

negative connecting cable of transmitter 

gn/ye, green / yellow) 

cable shield of transmitter 

 

positive signal line for pressure signal 

supply - 

negative signal line for pressure signal 

ground clamp 

cable shield of supply line and solid wire (with 
overvoltage protection) 

HART

-modem 

For more information, please read the detailed operating manual! 

housing: 58 mm. 

height of  
housing: 55 mm. 

KL 2

 

hole 

housing depth 

58 mm. 

housing depth 

55 mm. 

cable gland  

M16x1.5 

(cable 

Ø

5 ... 10 mm) 

pressure  

balance item 

mounting hole 

 4,2 

HA_ 
ON 

HART

 

Отзывы: