MULTI-PARAMETER 

PATIENT SIMULATOR 

 

 

 

 

 

 

 

 

 

PS-2105 

 

USER MANUAL 

 

 

 

 
 

 

Содержание PS-2105

Страница 1: ...MULTI PARAMETER PATIENT SIMULATOR PS 2105 USER MANUAL...

Страница 2: ......

Страница 3: ...13 ECG PACEMAKER 20 ECG PERFORMANCE 22 TRAINING 24 SETUP 29 POWER UP SETTINGS 31 SpO2 OPTION 33 OUTPUT CONNECTIONS 34 MANUAL REVISIONS 35 LIMITED WARRANTY 35 SPECIFICATIONS 36 NOTES 38 BC BIOMEDICAL...

Страница 4: ...necting the DUT to the PS 2105 A serious hazard may occur if the patient is connected when testing with the PS 2105 CAUTION MODIFICATIONS The PS 2105 is intended for use within the published specifica...

Страница 5: ...ION INSPECTION The PS 2105 should be inspected before each use for obvious signs of abuse or wear The PS 2105 should not be used and should be serviced if any parts are in question CAUTION CLEANING Do...

Страница 6: ...tested by an independent accredited testing laboratory and compliance was demonstrated to the above standard to the extent applicable EMISSIONS Radiated Emissions EN 61326 1997 Annex C IMMUNITY CLASS...

Страница 7: ...BREVIATIONS AHA American Heart Association ANSI American National Standards Institute BPM Beats Per Minute C Celsius degree s DUT Device Under Test ECG Electrocardiogram F Fahrenheit Hz hertz IEC Inte...

Страница 8: ...ANUAL HAS BEEN CAREFULLY CHECKED AND IS BELIEVED TO BE ACCURATE HOWEVER NO RESPONSIBILITY IS ASSUMED FOR INACCURACIES NOTICE CONTACT INFORMATION BC BIOMEDICAL BC GROUP INTERNATIONAL INC 3081 ELM POINT...

Страница 9: ...R OR ENTER GRAPHICS DISPLAY WITH SIMULTANEOUS DETAILED STATUS OF PARAMETERS AND SCROLLING CONTROL OF OPTIONS DROP DOWN CHOICE SCREENS LIST ALL OPTIONS FOR PARAMETERS SPECIAL POWER UP FEATURE ALLOWS TH...

Страница 10: ...0 mV Lead II AUTOMATIC MODE PACEMAKER FUNCTIONS Seven different pacemaker waveforms may be simulated Additionally the width and amplitude of the pacer pulse may be selected Available settings WAVEFORM...

Страница 11: ...e exact training requirement Available settings TIMER MANUAL 10 15 20 25 30 SEC RANDOMIZER OFF ON ARRHYTHMIAS ALL SUBSET SPO2 SIMULATION Option When used with the MSP 2100 external module and FingerSi...

Страница 12: ...Off 10 Universal Patient Lead Connectors RA R LA L RL N LL F V1 C1 V2 C2 V3 C3 V4 C4 V5 C5 V6 C6 9V Battery Compartment Back 7 Light Touch Keys for Selecting Parameters and Settings LEFT and RIGHT Cur...

Страница 13: ...ailable for selection The keys change the options for the highlighted parameter The cursor begins flashing if the parameter has been changed The key selects the changed option The key returns to the p...

Страница 14: ...a choice The key enters the pacemaker category and changes the first line in the display to the first pacemaker waveform choice The key enters the machine performance testing category and changes the...

Страница 15: ...cklight can be adjusted in the System Setup screen to conserve battery life The key is provided to toggle the backlight on or off at any time NOTE The backlight parameter in the System Setup screen ma...

Страница 16: ...rresponding U S and International Patient Leads AHA Label IEC Label Description RA R Right Arm LA L Left Arm RL N Right Leg reference or ground LL F Left Leg V1 V2 V3 V4 V5 V6 C1 C2 C3 C4 C5 C6 V Lead...

Страница 17: ...replaced before the battery reaches a critical level 0 Battery Life the unit will shut down The percentage of life left in the batteries can be viewed in the System Setup screen Battery Eliminator Th...

Страница 18: ...setting In each of these the unit will sequence through the full range of settings automatically at a fixed rate as selected in the Auto Step Time Parameter When in this mode the time remaining in ea...

Страница 19: ...ST Segment elevation The PS 2105 is placed into NSR mode by pressing the category key The display will resemble the following 30 BPM 40 BPM 45 BPM 60 BPM 80 BPM 90 BPM 100 BPM 120 BPM 140 BPM 160 BPM...

Страница 20: ...roll to the desired option Then is used to accept the new setting Auto Rate If the BPM parameter is set to AUTO the unit will automatically sequence through all of the BPM settings starting with 30 BP...

Страница 21: ...1 PVCs Auto Run of 11 PVCs Man 6 PVCs per Min 12 PVCs per Min 24 PVCs per Min Freq Multifocal PVCs Bigeminy Trigeminy Vent Tach Vent Fib Coarse Vent Fib Fine Asystole Conduction 1 st Deg Heart Block 2...

Страница 22: ...the desired option Then is used to accept the new setting NOTE While in the Arrhythmia Group choice screen the key may be used for a second time to jump directly to the arrhythmias choices for that gr...

Страница 23: ...Periodic Abnormal 25 early Nodal beat One Time event PVC 1 Auto Standard Type 1 Premature Ventricular Contraction NSR of 80 BPM with periodic left focus premature ventricular beats with 20 premature...

Страница 24: ...ntraction NSR of 80 BPM with periodic right focus premature ventricular beats with 33 premature timing PVC Type 2 9 NSR Continuous PVC 2 Early Man Early Type 2 Premature Ventricular Contraction NSR of...

Страница 25: ...seconds followed by a repeating sequence of 2 atrial beats and 1 ventrical beat for six seconds Continuous Atrial Tach Atrial Tachycardia 160 BPM Continuous Paroxysmal Atrial Tach Paroxysmal Atrial T...

Страница 26: ...roup of 11 Type 1 PVCs 11 PVC Type 1 36 NSR Continuous Run of 11 PVCs Man Run of 11 Premature Ventricular Contractions NSR of 80 BPM with periodic group of 11 Type 1 PVCs One Time event 6 PVCs per Min...

Страница 27: ...mia Description 1st Deg Heart Block First Degree Heart Block 80 BPM with a long P R interval of 250 ms Continuous 2nd Deg Heart Block Second Degree Heart Block 80 BPM with increasing P R interval for...

Страница 28: ...ls can be selected by using to highlight the parameter to change and using to scroll to the desired option Then is used to accept the new setting Alternately to see a submenu of all the options for a...

Страница 29: ...d no P wave Non Capture Ventricular Pacemaker Wave with Periodic Non Response 75 BPM Ventricular Paced beats with every tenth beat not responding Non Function Ventricular Pacemaker Wave with no Heart...

Страница 30: ...lowing These waves and amplitudes can be selected by using to highlight the parameter to change and using to scroll to the desired option Then is used to accept the new setting Square Wave 125 Hz Squa...

Страница 31: ...is set to AUTO the unit will automatically sequence through all of the performance waves starting with Square Wave 125 Hz incrementing at a fixed interval The interval may be set in the System Setup...

Страница 32: ...sets of the Arrhythmias can be selected to allow for individualization The PS 2105 is placed into TRAINING mode by pressing the category key The display will resemble the following The Timer Randomize...

Страница 33: ...in the timed mode the unit will switch to the next arrhythmia automatically at the set time If in the manual mode use to go to the next arrhythmia when ready To pause or exit the Training Mode during...

Страница 34: ...arking those specific arrhythmias or groups of arrhythmias of interest After a subset of arrhythmias has been selected it will remain in memory It may then be edited at any time prior to starting a tr...

Страница 35: ...play the list of arrhythmias for a specific group Then use to scroll through the arrhythmias Any arrhythmia marked with a check will be included in the subset Use to toggle the selection of an arrhyth...

Страница 36: ...rom that group use to return to the Group Submenu SOME will appear to indicate a partial selection of the arrhythmias in that group Additional groups may be modified in the same manor When done with a...

Страница 37: ...ontrolling various function of the unit as well as the viewing of Battery Life and Software information The display will resemble the following These settings can be selected by using to highlight the...

Страница 38: ...manually controlled by backlight key Off 1 30 sec Manual Backlight Intensity Sets the intensity of the backlight Note Lower intensities extend battery life 0 100 Battery Life Displays current life of...

Страница 39: ...wing settings will be used every time the unit is turned on ECG NSR 80 BPM 1 0 mV Adult QRS 0 0 mV ST Elevation Artifact None SpO2 Output Disabled ECG Arrhythmia 1 0 mV Artifact None Premature Atrial...

Страница 40: ...ser may save a unique set of default parameters and the unit will recall them every time the power is turned on Set Current As Custom To create the set of custom default parameters this fourth choice...

Страница 41: ...BPM rate up to 180 BPM The output is off in Arrhythmia and Performance Modes The module plugs directly into the AUX 7 pin mini din connector and is powered from the PS 2105 The output is only functio...

Страница 42: ...34 The following is a representation of the socket connector found on the unit It is viewed as if looking at the socket in the unit not the cable pins OUTPUT CONNECTIONS...

Страница 43: ...NTY IS EFFECTIVE FOR TWELVE MONTHS FROM THE DATE OF SHIPMENT EXCLUSIONS THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHAN...

Страница 44: ...60 120 BPM 60 ms width ACCURACY 1 AMPLITUDE 0 5 1 0 1 5 2 0 mV Lead II ACCURACY 2 Lead II HIGH LEVEL OUTPUT 200 times Amplitude ACCURACY 5 QRS DURATION ADULT 80 ms PEDIATRIC 40 ms ST SEGMENT ELEVATION...

Страница 45: ...80 x 6 04 x 1 72 Inches 223 5 x 153 4 x 43 7 mm WEIGHT 2 Lbs 0 91 kg OPERATING RANGE 15 to 40 C 59 to 104 F STORAGE RANGE 20 to 65 C 4 to 149 F ELECTRICAL BATTERY 9V Alkaline Battery 2 Required ANSI...

Страница 46: ...38 NOTES...

Страница 47: ......

Страница 48: ...ONAL INC 3081 ELM POINT INDUSTRIAL DRIVE ST CHARLES MO 63301 USA 1 800 242 8428 1 314 638 3800 www bcgroupintl com sales bcgroupintl com PS 2105 Patient Simulator User Manual 03 13 Rev 05 Copyright 20...