BC Biomedical PS-2010 Скачать руководство пользователя страница 15

 

 

 

 

 

 
 

PATIENT SIMULATION

 

RATE 

 

NORMAL SINUS 

RHYTHM  

30, 60, 120, 240 BPM 

PERFORMANCE 

WAVEFORMS  

SINE  

10, 60, 100 Hz  

SQUARE 

0.125, 2.0 Hz 

TRIANGLE 

2.0 Hz 

ACCURACY 

± 0.5 % 

AMPLITUDE 

LEAD 1 

1.75 mV 

LEAD 2 

2.75 mV 

LEAD 3 

1.00 mV 

ACCURACY 

± 2 % Lead II 

IMPEDANCE 

LEAD TO LEAD 

1000  Ω 

LEAD TEST 

< 1000  Ω 

 

PHYSICAL & ENVIRONMENTAL

 

CONSTRUCTION 

ENCLOSURE 

ABS Plastic 

FACEPLATE 

Lexan, Back printed 

SIZE 

7.26 x 4.46 x 1.51 Inches 

(184.4 x 113.3 x 38.4 mm) 

WEIGHT 

≤ 1 Lbs (0.45 kg) 

OPERATING RANGE 

15 to 40 °C (59 to 104 °F) 

STORAGE RANGE 

-20 to 65 °C (-4 to 149 °F) 

 

ELECTRICAL

 

BATTERY 

9 V Alkaline Battery 

(ANSI/NEDA 1604A or equivalent) 

BATTERY ELIMINATOR 

(Optional) 

9VDC, 50 mA 

 

BC20-21114 

 (Universal) 

SPECIFICATIONS 

Содержание PS-2010

Страница 1: ...ECG PATIENT SIMULATOR TEN LEAD PS 2010 USER MANUAL...

Страница 2: ......

Страница 3: ...7 NOTES 8 BC BIOMEDICAL PS 2010 TABLE OF CONTENTS CALIBRATION INTERVAL To ensure the accuracy of the PS 2010 Series BC Group International Inc recommends that it be calibrated at least once every 12...

Страница 4: ...WARNING USE The PS 2010 is intended for testing only and should never be used in diagnostics treatment or any other capacity where it would come in contact with a patient WARNING USERS The PS 2010 Se...

Страница 5: ...t the performance of the PS 2010 Allow the PS 2010 to acclimate to specified conditions for at least 30 minutes before attempting to operate it CAUTION LIQUIDS Do not submerge or spill liquids on the...

Страница 6: ...iv...

Страница 7: ...not directly connected to MAINS Under no circumstances should the terminals of the Analyzer be connected to any MAINS voltage NOTICE ABBREVIATIONS AHA American Heart Association ANSI American Nationa...

Страница 8: ...E RIGHT TO MAKE CHANGES TO ITS PRODUCTS OR SPECIFICATIONS AT ANY TIME WITHOUT NOTICE IN ORDER TO IMPROVE THE DESIGN OR PERFORMANCE AND TO SUPPLY THE BEST POSSIBLE PRODUCT THE INFORMATION IN THIS MANUA...

Страница 9: ...ECTORS ECG 30 60 120 AND 240 BPM SINE 10 60 AND 100 Hz SQUARE 0 125 AND 2 000 Hz TRIANGLE 2 000 Hz HIGH LEVEL OUTPUT 1 V p p AMPLITUDE ACCURACY 2 FREQUENCY ACCURACY 0 5 OF SETTING 9 VOLT BATTERY POWER...

Страница 10: ...ted 1 LED for Lead Test confirmation and 1 LED for Low Battery Indication LAYOUT High Level Output Lead Test Terminals 4 Light Touch Keys for Power and Waveform Selection On Off Up Down Universal Pati...

Страница 11: ...the High Level and RL N Patient Lead Connectors Waveform Selection There are two keys and 10 LEDs in the Waveform Selection Control Section The LEDs indicate which waveform is generated The keys seque...

Страница 12: ...The unit will automatically turn off after 10 minutes of no key activity to conserve the battery To override this feature and keep the unit on continuously depress the key twice after the unit is on T...

Страница 13: ...ttery Eliminator Input A 2 1 mm receptacle is provided for the optional 9 VDC Battery Eliminator power supply that may be used for continuous run applications It bypasses the internal battery when plu...

Страница 14: ...E INTENDED THIS WARRANTY IS EFFECTIVE FOR TWELVE MONTHS FROM THE DATE OF SHIPMENT EXCLUSIONS THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIE...

Страница 15: ...IMPEDANCE LEAD TO LEAD 1000 LEAD TEST 1000 PHYSICAL ENVIRONMENTAL CONSTRUCTION ENCLOSURE ABS Plastic FACEPLATE Lexan Back printed SIZE 7 26 x 4 46 x 1 51 Inches 184 4 x 113 3 x 38 4 mm WEIGHT 1 Lbs 0...

Страница 16: ...8 NOTES...

Страница 17: ...9 NOTES...

Страница 18: ...10 NOTES...

Страница 19: ......

Страница 20: ...INTERNATIONAL INC 3081 ELM POINT INDUSTRIAL DRIVE ST CHARLES MO 63301 USA 1 800 242 8428 1 314 638 3800 www bcgroupintl com sales bcgroupintl com PS 2010 User Manual 12 21 Rev 06 Copyright 2021 Made i...

Отзывы: