TROUBLESHOOTING – BATTERY CHARGER OPERATING MODE 

ANOMALIE CAUSE RIMEDI 

1.

 

The display shows the error message: “Load not connected” 

 

No battery is connected to the device -> Check battery connection 
 

2.

 

The display shows the error message: “Short/Pol. Inverted” 

 

Battery connected with reverse polarity -> Connect the red terminal to the battery positive pole (+) 
and the black terminal to the battery negative pole (-) 
Short circuited battery -> Replace battery 
Short circuit on the output of BC X-PRO 130 -> Please ask the manufacturer or an authorized service 
center for support 

 

3.

 

The display shows the error message: “Mains not connected” 

 

BC XPRO 130 not connected to power supply -> Connect the device to the mains and turn it on by 
putting the switcher in “I” position.  
 

4.

 

The display shows the error message: “Weak battery” 

 

The  Battery Check step  detected  that  the  battery  is not  able to  retain  the  charge  ->  Replace  the 
battery 
 

5.

 

The display shows the error message: “Psu internal error” 

 

Internal  problem  inside  BC  X-PRO  130  ->  Please  ask  the  manufacturer  or  an  authorized  service 
center for support 

 
 
 
 
 
 
 

Содержание X-PRO 130

Страница 1: ...ble voltage during diagnosis operations and flash programming on the vehicle compensating for the energy absorption of the on board devices fan electronic suspension electric windows It is possible to...

Страница 2: ...nd place the battery in a well ventilated area to avoid any risk of fire or explosion Protect the battery surface from any risk of short circuits Batteries contain a corrosive electrolyte Wear protect...

Страница 3: ...uages Proceed as follows 1 Press and hold the ON OFF SELECT button for 5 seconds to access the menu 2 Press the arrow keys until you reach Menu Language Press ON OFF SELECT to confirm 3 Select the des...

Страница 4: ...type with the arrow keys STD MF Lithium AGM EFB Ca Ca Press the ON OFF SELECT button to confirm the choice 5 Select the maximum charging current with the arrow keys Note select a maximum charging cur...

Страница 5: ...the limit press the arrow button until you reach OFF Press the ON OFF SELECT button to confirm the choice The safety parameters set in this way are saved in memory for subsequent uses START STOP THE...

Страница 6: ...a specially designed electronic circuit the device maintains the battery fully charged during periods of inactivity sen without any overheating overcharging or electrolyte loss Step 11 Equalization du...

Страница 7: ...supply current with the arrow keys between 1 A and 130 A Press the ON OFF SELECT button to confirm the choice The display indicates OK BC X PRO 130 restarts and the first row of the display shows the...

Страница 8: ...to confirm the choice The display indicates OK BC X PRO 130 restarts with the last used configuration and with SHOWROOM mode active In the event of a power failure for example when the power is turne...

Страница 9: ...s provided with an internal protection fuse against connection mistakes by the user MAINTENANCE If the power cable is damaged do not use the product but ask for replacement or repair by the manufactur...

Страница 10: ...ttery Short circuit on the output of BC X PRO 130 Please ask the manufacturer or an authorized service center for support 3 The display shows the error message Mains not connected BC XPRO 130 not conn...

Страница 11: ...to the mains and turn it on by putting the switcher in I position 4 The display shows the error message Supply overload The loads connected require too much current BC X PRO 130 cannot keep the set v...

Страница 12: ...problem inside BC X PRO 130 Please ask the manufacturer or an authorized service center for support TECHNICAL DATA Input Voltage 100 240V ac 50 60Hz Charging Voltage 13 8V 14 7V nom 12V Charging Curr...