background image

SDS1 Connections:

J1 DB9 MALE

TX1000 Keyboard

J2 

TX1000 Base Unit Connections.

RED

+12V

BLUE

DATA RX

GREEN

DATA TX

WHITE

GND

J3 

Video Transmission Equipment

.

RS232

RS232 DATA IN

NO

Normally-open relay contacts

COM

Relay Contacts Return

GND

0V Ground Connection

          

J2

J3

View of SDS1 PCB.

Wago Connectors

The Wago series 233 PCB terminal block is
a simple-to-use method of attaching cables
to PCB’s quickly and easily. The correct
method of attachment is illustrated to the
left.

CONNECTION TO SLAVE KEYBOARD

When using the SDS1 to switch to a second TX1000 slave keyboard, an SPST switch will be
required to changeover the data input. This will connect between J3 NO and J3 COM. The
GREEN DATA TX from the TX1000 will need to be connected to the lead for the keyboard,
this enables LED function on the second slave. Using the leads supplied the female ended
lead connects to the TX1000 Base Unit and the coloured wires are connected to the SDS1 as
shown in the diagram. The male-ended lead connects to the Slave Keyboard lead and the
coloured wires are connected as follows:

Wire Colour (male ended)

SDS1 Connection (refer to diagram)

Red

Not Connected

Blue

J3 RS232 DATA IN

Green

J2 GREEN Data TX from base unit

White

J3 GND

Orange & Black 

(if present)

Not Connected

CONNECTION TO PL1 PROTOCOL CONVERTER WHEN USING DM’S DVST.

Using the leads supplied the female ended lead connects to the TX1000 Base Unit and the
coloured wires are connected to the SDS1 as shown in the diagram above. The male-ended
lead connects to the PL1 and the coloured wires are connected as follows:

Wire Colour (male ended)

SDS1 Connection (refer to diagram)

Red

J2 RED +12V

Blue, Black & Orange

Not Connected

Green

J3 RS232 IN

White

J3 GND

On-line relay connections to Dedicated Micros DFT150/200

Pin 19 (37 way D type Alarm I/O Connector)

J3 NO

Pin 37 (37 way D type Alarm I/O Connector)

J3 COM

SDS1 Installation Guide. Issue 1.0 27 January 1999

Page 4

1.   INSERT SCREWDRIVER
      PRESS LEVER TO OPEN 
      CAGE CLAMP

2.   INSERT STRIPPED 
      CONDUCTOR

RELEASE
LEVER      3.

Отзывы: