BBV RX 459 Скачать руководство пользователя страница 1

Building Block Video RX55X Set-up sheet   JDC 25 May 2004 version 10 code. 

BBV RX45X or 55X Quick Start Set-up Guide 
 

The Unit is shipped as a BBV Coax receiver. Using the procedure below the 

following receiver types can be obtained. 
 
RX 459 / RX559 BBV coax receiver 

RX 457 / RX557 BBV Rs485 protocol receiver 
RX 454 / RX554 Dennard Rs485 protocol receiver 
RX 453 / RX553 Phillips Biphase receiver only with factory fitted option board 

RX 452 / RX552 VCL Rs485 protocol receiver 
RX 451 / RX551 Pelco P protocol receiver 
RX 451 / RX551 Pelco D protocol receiver 

 
To change it to any other protocol please plug a monitor on the To Matrix 

BNC and a video source to the Camera BNC and press the MENU/SET key.  
The on screen display produces a menu. 
Select Communications by pressing the MENU/SET key. 

Then using the UP and DOWN and MENU/SET keys, select Menu Unlock 
and unlock the Comms menu. Using the UP key move up to Telemetry 
Type
 and Select. 

Using the UP and DOWN Keys select the appropriate receiver type. 
Press the SET key to fix the type, then select  Fix the changes and exit 
to fix the receiver type. 

 

The Units address can be set in a similar way by selecting Unit Address in 
the communications menu.  
 
New features added  
 

 

The unit as a coax receiver allows full testing of the head wiring and correct functionality using a 
simple TX400. 

 

 

The unit allows automatic switching between ac and dc variants of the unit. 

 

The unit supports camera addresses up to 30000 on the Philips RX453/ 553 unit.  

 

The unit supports both the Pelco P and D protocols on the Pelco RX451/551 unit. 

 

The unit supports  Sine Cosine continual rotation heads, with shortest path preset hunting. 

 

Support for privacy zone board programming. 

 

Direct updating of the boards features using a TXLD via the camera port.

 

.

 

Отзывы: