![BBQ GPF2414AE Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/bbq/gpf2414ae/gpf2414ae_instruction-manual_2713927021.webp)
GPF2414AE
Instruction Manual
20
Troubleshooting
Problem
Possible Cause
Prevention/Cure
B
urner will not light using knobs or
igniter.
Wires and/or electrode covered with
cooking residue.
Electrode and burners are wet.
Electrode cracked or broken –
sparks at crack.
Wire loose or disconnected.
Clean wire and /or electrode with
rubbing alcohol.
Wipe dry with cloth.
Replace electrode.
Reconnect wire or replace electrode/
wire assembly.
Burner will not light using a match.
No gas flow.
Coupling nut and regulator not fully
connected.
Obstruction of gas flow.
Disengagement of burner to valve.
Spider webs or insect nest in venturi.
Burner ports clogged or blocked.
Check if propane tank is empty. If
empty, replace or refill. If propane
tank is not empty, refer to
Excessive flow safety valve
reset procedure
on page 18.
Turn the coupling nut about
one-half to three quarters
additional turn until solid stop.
Tighten by hand ONLY - do not
use tools.
Clear burner tubes.
Check for bent or kinked hose.
Reengage burner and valve.
Clean venturi.
Clean burner ports.
Irregular flame pattern, flame does not
run the full length of burner.
Burner ports are clogged or blocked.
Clean burner ports.
Flame is yellow or orange.
New burner may have residual
manufacturing oils.
Spider webs or insect nest in
venturi.
Food residue, grease or seasoning
salt on burner.
Poor alignment of valve to burner
venturi.
Burn grill for 15 minutes with the lid
closed.
Clean venturi.
Clean burner.
Assure burner venturi is properly
engaged with valve.
Sudden drop in gas flow or reduced
flame height.
Tank out of gas.
Excess flow safety device may
have been activated.
Check for gas in propane tank.
Refer to the
Excess flow safety valve
reset procedure
on page 18.