5
.3 MISCELLANEOUS
5
.3.1 Protection of the LD(Laser diode)
Short the parts of LD circuit pattern by soldering.
5
.3.2 Cautions on assembly and adjustment
Make sure that the workbenches,jigs,tips,tips of soldering irons and measuring instruments are
grounded,and that personnel wear wrist straps for ground.
Open the LD short lands quickly with a soldering iron after a circuit is connected.
Keep the power source of the pick-up protected from internal and external sources of electrical
noise.
Refrain from operation and storage in atmospheres containing corrosive gases (such as H2S,SO2,
NO2 and Cl2)or toxic gases or in locations containing substances(especially from the organic silicon,cyan,
formalin and phenol groups)which emit toxic gases.It is particularly important to ensure that none of the
above substances are present inside the unit.Otherwise,the motor may no longer run.
Содержание Dk960S
Страница 1: ...TUNED ST 3D MEM AM ALL FM VOL1 VOL2 SERVICE MANUAL Dk960S ...
Страница 7: ...5 1 Optical pickup Unit Explosed View and Part List Pic 1 ...
Страница 13: ......
Страница 45: ......
Страница 47: ......
Страница 50: ......
Страница 51: ......
Страница 53: ......
Страница 60: ......