4.6.12. Scope Onlinediagnostics
Setting the drive monitoring requires an exact knowledge of the process data from the point of view
of the SCU system. Knowledge of the chronological sequence of speed, acceleration and position
is paramount. Only in this way, correct threshold values and restrictive parameters can be set.
The range function is available in the dialogue window oft he device interface. You select the range
monitoring by activating the
“Scope” button.
If the diagnosis button is enabled
, the “Scope” button
is deenabled immediately.
Figure 82 Range view in the device interface
1-
Overview scroll bar
2-
Main diagram window
3-
Signal output window
All available graphic functions read the required process data ONLINE from the active SCU via the
communication station for time-based display. Current values are displayed on the right side of the
range monitoring, move to the left during the recording and then disappear from the left edge of the
screen. Even if these data have disappeared from the visible window, they are saved in a cache
memory. They can be made visible again by dragging the scroll bar beyond the main window.
Figure 83 Overview of the scroll bar for the main diagram
Plan:
With the
“Plan” f
unction, the current context for the desired visualization
“
can be selected.
The context of the displayed curves changes according to the selection of the plan. To the curves a
colour is assigned that is specified in the key.