1
+
2032
175
189
138
50.8
10.8
4.8
175
189
50.8
138
10.8
4.8
175
189
50.8
138
10.8
4.8
RF
Gate
2.1
i
i
Wireless signal transmission system for safety edges
Translation of original operating instructions
General
1
Safety instructions
2
Common application
ENGLISH
290260G
10/18
Transmitter
Receiver
Warning:
Switch off the operating voltage before working on the
system. Only trained, qualified personnel may perform installation
and startup. The unit may only be repaired by the manufacturer. The
switching unit may only be used to protect against dangers on
crushing and shearing points and on automatic industrial doors and
gates (intended use). National and international regulations on
industrial door and gate safety must be complied with. Always
consider the safety functions of your application as a whole, never just in
relation to one individual section of the system. The installer is responsible
for carrying out a risk assessment and installing the industrial door system
correctly.
It is recommended to change the batteries every year.
2.1 Site entrance gate
Safety edges
Receiver
Safety edges
8.2kΩ
Transmitter
i
Up to 10 transmitters can be linked with
the same receiver
Transmitter
Transmitters and receivers (also among each others) must be at
least 0.5 m apart.
i