background image

1

+

2032

175

 

189

 

138

50.8

 

10.8

 

4.8

 

175

 

189

 

50.8

138

 

10.8 

4.8

 

175

 

189

 

50.8 

138

 

10.8 

4.8

 

RF

Gate 

2.1

i

i

Wireless signal transmission system for safety edges

Translation of original operating instructions

General

1

Safety instructions

2

Common application

ENGLISH

290260G

10/18

Transmitter

Receiver

Warning:

 Switch off the operating voltage before working on the 

system. Only trained, qualified personnel may perform installation 
and startup. The unit may only be repaired by the manufacturer. The 
switching unit may only be used to protect against dangers on 
crushing and shearing points and on automatic industrial doors and 
gates (intended use). National and international regulations on 
industrial door and gate safety must be complied with. Always 

consider the safety functions of your application as a whole, never just in 
relation to one individual section of the system. The installer is responsible 
for carrying out a risk assessment and installing the industrial door system 
correctly. 

  It is recommended to change the batteries every year.

2.1   Site entrance gate

Safety edges

Receiver

Safety edges

8.2kΩ

Transmitter 

i

Up to 10 transmitters can be linked with  
the same receiver

Transmitter

Transmitters and receivers (also among each others) must be at 

least 0.5 m apart.

i

Содержание RFGate 2.2.S

Страница 1: ... against dangers on crushing and shearing points and on automatic industrial doors and gates intended use National and international regulations on industrial door and gate safety must be complied with Always consider the safety functions of your application as a whole never just in relation to one individual section of the system The installer is responsible for carrying out a risk assessment and...

Страница 2: ... MHz Set DIP switch before pairing transmitter receiver 1 2 3 4 ON Test input type NC activated contact open 1 2 3 4 ON NO activated contact closed 1 2 3 4 ON Automatic frequency adjustment active used only in case of radio disturbances 1 2 3 4 ON inactive factory setting Observe the sequence Relay contacts are shown unpowered 4 2 Wiring Outputs and control Gate control with NC input Gate control ...

Страница 3: ...r transmitter with receiver Transmitters and receivers also among each others must be at least 0 5 m apart Observe order 6 2 Clear pairings 6 3 Memory full Press button and hold Keep pressed the button Short beeps Beep Wait Release button 10 sec 1 5 sec 3 sec 2 beeps Code saved LED goes out Please observe the torque when fastening the cover Max 45 N cm 7 Transmitter wire 3 Turn on power supply 2 I...

Страница 4: ...put See page 2 chapter 4 1 I 3 mA switching threshold off 0 6 V on 1 8 V Transmitter Battery power 2 x Lithium 3 V Type CR2032 Power consumption Transmitting 17 mA standby 16 µA Safety OK LED on Battery voltage low System Frequency bands 868 95 MHz 869 85 MHz Range under optimum conditions up to 100 m Protection class IEC 60529 IP55 Pollution degree 2 Working temperature 20 C to 55 C Beep 9 EU Dec...

Отзывы: