DS-SERIES OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
30
NOTE:
DTR is unchangeable when configuring the serial port.
When configuring the Host Modem, Xon/Xoff, RTS, and DTR are
hardware settings and, therefore, unchangeable.
For example, to change the baud rate to
115.2K, select #2, “Set Baud Rate,” followed
by <cr>.
The DS71-MD2 displays the following list of
available baud rates:
1 for 300
2 for 600
3 for 1200
4 for 2400
5 for 4800
6 for 9600
7 for 19200
8 for 38400
9 for 57.6K
A for 76.8K
B for 115.2K
Enter Request :
Type "B" for 115.2K baud rate. The DS71-
MD2 responds with the new configuration
status:
Module 1 Serial Port Configuration :
Port
Device
Name
Baud
Rate
Word
Size
Stop
Bits
Parity
Xon/
Xmit
Xoff/
Recv
Line
DTR
Drive
RTS
2
Host MODEM
115.2K
8
1
None
Off
Off
High
High
Exit/Save..….......1 Set Parity...….........5
Set Baud Rate….2 Set Xon/Xoff….......6
Set Word Size….3 RTS Line Driver....7
Set Stop Bits..…..4 DTR Line Driver...8
Enter Request :
Содержание DS3
Страница 8: ......
Страница 81: ...DS SERIES OWNER S MANUAL APPENDIX D 73 APPENDIX D DRAWINGS DS71 MECHANICAL LAYOUT ...
Страница 82: ...DS SERIES OWNER S MANUAL APPENDIX D 74 DS71 MD2 MECHANICAL LAYOUT ...
Страница 83: ...DS SERIES OWNER S MANUAL APPENDIX D 75 DS74 MECHANICAL LAYOUT ...
Страница 84: ...DS SERIES OWNER S MANUAL APPENDIX D 76 DS73 MECHANICAL LAYOUT ...
Страница 85: ...DS SERIES OWNER S MANUAL APPENDIX D 77 DS71 FACEPLATE LAYOUT ...
Страница 86: ...DS SERIES OWNER S MANUAL APPENDIX D 78 DS71 MD2 FACEPLATE LAYOUT ...
Страница 87: ...DS SERIES OWNER S MANUAL APPENDIX D 79 DS73TP FACEPLATE LAYOUT ...
Страница 88: ...DS SERIES OWNER S MANUAL APPENDIX D 80 DS74 FACEPLATE LAYOUT ...