PM5-REL-4 Relay Module – User Manual
2
1
Identification of safety information
Please refer to the information concerning the
identification of safety information in your PoolManager
®
or Analyt user manual.
2
General safety information
HAZARD!
Please follow the general safety information
in your PoolManager
®
or Analyt user manual
carefully.
3
User qualification
Please refer to the different user qualifications as defined
in your PoolManager
®
or Analyt user manual.
4
Overview
The PM5-REL-4 Relay Module is a plug-in module for the
BAYROL Measuring, Control und Dosing Systems
PoolManager
®
and Analyt of the 5th generation (from
2012). It provides 4 additional relay outputs which can be
flexibly used for various add-on functions. Each single
relay can switch max. 3A at
230V~or
30V=.
5
Installation
This chapter describes the installation of the PM5-REL-4
plug-in module inside the PoolManager
®
controller and
the cable connections.
Required user qualification:
ELECTRICAL SPECIALIST
Electrical connection may only be performed by
an ELECTRICAL SPECIALIST as defined in the
chapter
User qualification
of
your PoolManager
®
or Analyt user manual
.
5.1
Opening the casing
HAZARD DUE TO VOLTAGE!
Inside the controller you may get in touch with
dangerous electrical voltages.
Potential consequence: Death or the gravest
degree of injury.
Disconnect the controller from mains power
supply before opening the casing and, in
particular, the lid of the connection terminal box.
IMPORTANT NOTICE!
Open on the right
Never open the casing on the left side, as
damage may otherwise occur.
Always open on the right side!
1.
Firmly press the hinge on the right side out and to
the right.
2.
Remove the cover plate and unhook the hinge on the
bottom.
3.