CHAPTER 2: FEATURES / SYSTEMS 23
Ciera 2858 Command Bridge
•
Owner’s Manual Supplement
Sink & Shower Drain Systems
Gray water (water from sinks and showers)
above the waterline is gravity drained over-
board, while gray water below the water-
line is pumped overboard using a sump
pump.
The sump box (A), containing the shower
sump pump, float switch, and filter is
located under the middle entry step (B) (see
the illustration on the right).
Sump Box Cleaning
The sump box, filter, and pump should be
periodically cleaned of debris as follows:
1.
Remove the cover screws (C) and
the cover (D).
2.
Remove any debris from the box and
the filter.
3.
Clean the sump pump as outlined in
the bilge pump section of
this Supplement.
Sump System Winterization
Drain the sump pump system in the winter
months when not in use.
1.
Disconnect and drain all lines to
the unit.
2.
Remove the screws from the mounting
feet (E) and drain the system.
3.
Reinstall the screws in the mounting
feet and reconnect the system.
HOT HAZARD! Water heated by the water heater can reach temperatures high enough
to scald the skin.
WA R N I N G !
!
WATER HEATER DAMAGE HAZARDS!
•
DO NOT energize the AC water heater electrical circuit until the heater is completely filled
with water. Even momentary operation in a dry tank will damage the heating elements.
Warranty replacements will not be made on elements or tank damaged in this manner. The
tank is full if water flows from the tap when the hot water is turned on in the galley.
•
The water heater should be drained and the power turned OFF when the possibility of
freezing exists.
CAUTI ON!
!
A
C
E
D
SUMP PUMP ACCESS