Attention:

Clean all parts before using the Pralinenfix

Cleaning and assembling piston unit 

Cleaning 

All parts of the container and the piston unit can be 
cleaned both by hand and in the dishwasher.
We recommend a temperature setting of approx. 70°C
The simplest manner of cleaning is by hand using the enclosed
 brush and a normal washing up liquid  (e.g. Pril).

For cleaning in the dishwasher use a 
normal household liquid  (e.g. Somat).

The cylinder tube and nozzle must be positioned in the direction of rinsing 

(usually vertical) to ensure that they are also cleaned inside. 

Assembly 

Before assembling the piston unit, the 

cylinder

 and the 

nozzle ring 

must be greased 

slightly from the inside  

(e.g. with Palminsoft). 

   Annex 3   PFM 2000

    2011-01-28

Grease 

inside 

of cylinder 

and nozzle ring slightly with 
Palminsoft. 

Dismantled piston unit 

Piston 

Cylinder

Nozzle ring with 
nozzle 

Valve rubber 

Screw lid 

Содержание PFM 2000

Страница 1: ...Pralinenfix PFM 2000 01 2011...

Страница 2: ...Annex 1 PFM 2000 2011 01 28 New Artikel Nr 29 10 08 Now available Especially for the filling of liquor we can now offer an new special nozzle r For more information talk to your Costumer consultant...

Страница 3: ...2 PFM 2000 2011 01 28 To guarantee a steady filling the following parts are to be greased after the cleaning We would therefore recommand Palminsoft Piston unit Container all O Rings Parts inside to g...

Страница 4: ...iquid e g Pril For cleaning in the dishwasher use a normal household liquid e g Somat The cylinder tube and nozzle must be positioned in the direction of rinsing usually vertical to ensure that they a...

Страница 5: ...apr 17 kg with container Container Container volume apr 5 litre Heating Power consumption 10 Watt Pre heating period 30 min Connection 230 V Type label Important information Our device complies with...

Страница 6: ...19 Screw lid 15 x 1 5 2 7 Gasket O ring 01 09 22 Cylinder 22 x 1 5 4 14 Gasket O ring 01 09 23 Piston 7 x 2 5 4 14 Valve rubber 29 14 26 Piston unit 15 x 20 4 7 Fixing ring O ring 01 09 18 Bridge 9 x...

Страница 7: ...n unit cpl 29 10 01 Piston 29 11 27 O ring 2x Art 01 09 23 7 x 2 5 Cylinder 29 11 20 O ringe 2x Art 01 09 22 22 x 1 5 O ring 1x Art 01 09 18 9 x 1 5 Nozzle ring with nozzle 29 10 07 Valve rubber Screw...

Страница 8: ...are dry and that there is no water residue Pre heat the basic device before starting l Attention Observe pre heating period See Page 1 Technical data Cleaning and care Attention l Remove mains plug b...

Страница 9: ...til 2 The cylinder must lie fully on the both bolts are latched into position bridge Page 5 Check O rings visually for damage Spray inside of cylinder tube and nozzle ring slightly with Palminsoft 2 1...

Страница 10: ...eel c to the left distance between nozzle and praline opening becomes bigger l Set the handwheel close to the praline opening so that the mixture is not dragged over the edge of the pralines Setting o...

Страница 11: ...g lever quickly through to the stop Injection procedure complete coating F Praline machine cleaned assembled and preheated l Attention No water residue in the entire machine F Alter settings at the ba...

Страница 12: ...ng connection as well as force majeure or other external influence are not covered by the guarantee Note Should the device not function correctly check whether the required settings were made in accor...

Страница 13: ...ure is not discharged from the nozzle Precision ball not installed Uneven dosage Valve rubber is damaged O ring is damaged After cleaning all O rings must be greased Mixture is dragged over the edge D...

Отзывы: