Problem
Probable Cause
Remedy
TROUBLESHOOTING GUIDE
Low Ticket LED not
working.
Power comes from the door
board
Ensure low ticket switch is
wired normally open.
Ensure the low ticket switch is
operating normally.
Ensure CE5187 cable is
plugged into door board
Disconnected, loose or broken
wires.
Faulty low ticket LED light
Check AACE5184 cable from low ticket switch to
the door board.
Check for continuity on the switch. Replace switch
if needed. Part # AASW200
Refer to Wiring Diagram from low ticket LED to
door board.
Check connections from door board to low ticket
LED. Cables #’s: CE5187 & AACE5193
Replace light if needed. Part # AACE5193
Tower not Recognized
on Win Tray
Place tower on tray - it
should be reloaded back
onto the playfield
Verify if problem is tower or
the tray itself.
Test RFID sensor on tray.
Verify 12 Volts DC to motor
when it should reload.
Ensure motor returns to home
position.
Identify a faulty Door Board
Place the same tower on a different Win Tray.
- If the different Win Tray also does not reload,
the tower is faulty and should be replaced.
- If the different Win Tray does reload, there is a
problem with the original tray. Continue below.
Check phone cable from RFID sensor to Door
Board. Part # AACE5189
Swap RFID sensor to different station to verify
operation. Replace if needed. Part # AACB5157
Swap reload tray assembly to a different station to
verify faulty motor. Replace if needed. AART5100
Check sensor on assembly. Replace sensor if
needed. Part # AACB5190A
Swap door board to different side to verify faulty
board Replace if needed AACB5159D-A-TR
Tower is not being
reloaded back onto
playfield
Game does pay tickets
correctly
Verify 12 Volts DC to motor
when it should reload.
Ensure motor returns to home
position.
Identify a faulty Door Board
Swap reload tray assembly to a different station to
verify faulty motor. Replace if needed. AART5100
Check sensor on assembly. Replace sensor if
needed. Part # AACB5190A
Swap door board to different side to verify faulty
door board. Replace if needed AACB5159D-A-TR
Reload tray does not
return to original
position
Place tower on tray after
game power on.
Ensure CE5187 cable is
plugged into door board
Disconnected, loose or broken
wires.
Faulty Reload Sensor
Faulty mechanical linkage
inside reload assembly.
Refer to Wiring Diagram from reload sensor to
door board.
Check connections from door board to reload
sensor. Cables #’s: AACE5188 & AACE5190A
Replace sensor if needed. Part # AACE5190A
Swap tray assembly to different station to verify
faulty mechanism. Replace if needed. AART5100