27
TROUBLESHOOTING GUIDE
7
Troubleshooting Strategy
Use common sense and a systematic method of troubleshooting to determine the exact problem, probable cause and
remedy. Use the process of elimination to find the faulty
component. Always check for the simple and obvious causes
first such as unplugged, loose or broken wires and bad
sensors, bent, pinched, stuck or jammed components.
Troubleshooting Chart
Problem
Probable Cause
Remedy
No power to the game.
No lights on at all.
Unplugged.
Circuit breaker tripped.
Line Filter Faulty.
Power strip faulty.
Faulty cable/power supply.
Check wall outlet.
Reset power strip breaker switch or building
circuit breaker.
Replace Line Filter (Part # A5FI9010)
Change plug position, replace if needed.
See Power Supply diagnostic below.
Bill Acceptor on.
But everything else off.
(Power Supply not ON)
Insure unit is plugged
into power strip.
Make sure rocker switch is
set ON.
See power supply diagnostics to isolate bad
component. A bad motor or 12 volt short
would cause this.
See Power Supply Diagnostic below.
Dollar Bill Acceptor not
functioning.
Ensure Bill Acceptor is set to
“Always Enable”
Important : Only 110 Volt AC
DBA is to be installed.
Enter Diagnostic Menu to see if
DBA input flashes ON quickly
when bill is inserted.
Look for “Check Minigen
Comm” error on screen.
Check for power to Bill
Acceptor.
Dirt or debris in acceptor slot.
Pinched, broken, or
disconnected wiring.
Bill acceptor problem.
Part # A5AC9093
110 VAC Downstacker
Refer to “Check Minigen Comm” error
diagnostic section.
Acceptor should cycle stacker at game
power up. If not, check cable connections.
Refer to “How to Clean Bill Acceptor”
Or clean with bill reader cleaning card.
(A5CC9000)
Check wiring from bill acceptor to Mini Gen
Board. (AACE3316, AACE3311)
Repair or replace wiring harness.
Check J9 connector on Main Board
Make sure wires are secure in connectors.
Refer to troubleshooting section of dollar bill
acceptor manual included with this game or
the diagnostics label of the back of the unit.
Power supply unplugged.
Rocker Switch.
Power supply shutting down
because of 12 V overload.
Faulty power supply.
Meters does not work.
Game/Credit meter has option in
menu to click as each coin is insert-
ed or click as each game is started.
Ticket meter will click as tickets
come out of game and notch is
“seen” by dispenser.
Ensure correct number of tick-
ets are being dispensed.
Disconnected, loose or bro-
ken wires.
Faulty counter.
Check ticket values. Refer to Tickets not dis-
pensing troubleshooting section.
Check connections and reseat J25 on Minig-
en board. Cables # AACE3319 and
AACE3320
Replace counter. AACE3320