background image

5135654/02

Model 

845 Dimension 

Electric Firefront.

Fitted with one of the following fascia:

Lyrica

or 

Nano. 

And for use with the 

Baxi Bermuda BBU15 HE 

Boiler.

(GC No. EF-032-38)

Important: Please keep your guide in a safe place for future reference.

INSTALLER AND OWNER GUIDE

This guide is intended to help you
install and care for your Valor Fires
Electric Firefront. Please read
carefully before installing and using
your firefront. However, if further
information is required, our

Valor Fires Technical Helpline

will

be pleased to help.
Telephone 

0844 8711 565 

(National

call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone

0044 844 8711 565.

© 

Baxi Heating U.K. Limited 2009.

Содержание VALOR FIRES 845

Страница 1: ...INSTALLER AND OWNER GUIDE This guide is intended to help you install and care for your Valor Fires Electric Firefront Please read carefully before installing and using your firefront However if furthe...

Страница 2: ...K Limited The Wyvern Business Park Stanier Way Derby DE21 6BF Warning Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims fo...

Страница 3: ...INSTALLER GUIDE Page 3 Baxi Heating U K Limited 2009 INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 16 TO 27...

Страница 4: ...the cable clamp 9 Do I need any tools 9 Where and how can you fit the firefront 9 General notes to read before fitting your firefront 10 Securing the Firefront 11 Method A Securing with wire 11 Metho...

Страница 5: ...firefront If for any reason this weight is considered too heavy then obtain assistance When lifting always keep your back straight Bend your legs and not your back Avoid twisting at the waist It is b...

Страница 6: ...or cover the fan outlet or force items into firefront openings Never install or use the firefront anywhere where water or high humidity is in use i e Bathrooms Kitchens Shower Rooms and Swimming Pool...

Страница 7: ...ension leads should not be used Never connect the boiler and firefront to the same socket spur The fuse ratings are different and subsequent damage may occur 3 OPTIONAL KITS Although the firefront is...

Страница 8: ...eating U K Limited 2009 Contents Quantity Illustrations are not to scale Firefront 1 Spacer frame 1 Only No 8 x 3 8 pan head screw 5 Tension wire 1 Eye screw 1 Cable clamp 1 Boiler Control and connect...

Страница 9: ...will need a Pozidrive Phillips cross head screwdriver This should have a number 2 size tip Where and how can you fit the firefront Q What opening size do you need in the surround or fireplace opening...

Страница 10: ...de completed There should be at least 10mm clearance between the top of the fascia and anything such as a shelf fireplace surround or mantel etc This will allow the fascia to be removed and fitted dur...

Страница 11: ...iler Control lead to the lead on the boiler and check the boiler operation 4 There is a supply cable slot on both sides of the spacer frame It is located at the base Decide which side to pass the supp...

Страница 12: ...ll hole on the left hand side of the firefront See figure 6 10 Locate the firefront in the fireplace opening then from the front of the firefront gently pull the steel wire on the right hand side to g...

Страница 13: ...necessary to purchase two kits they are designed to be secured together 1 There are four screws supplied with the optional spacer frame The narrow flange of the optional spacer should be placed agains...

Страница 14: ...ascia towards the heater to engage the magnets 4 Place the lower casting at the base of the firefront Fitting the Nano fascia 1 Remove the fascia from its packaging 2 There are three magnets on the fa...

Страница 15: ...ay from the work area 2 The firefront is is held in place with a single wire It will be necessary to loosen and remove the wire at one side Do this by placing a flat ended screw driver or similar tool...

Страница 16: ...Page 16 Baxi Heating U K Limited 2009 OWNER GUIDE OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 23 TO 27...

Страница 17: ...NT 23 5 WARRANTY AND SERVICE 23 CUSTOMER CARE Thank you for choosing Valor Fires All Valor Fires firefronts are designed to meet the most stringent quality performance and safety requirements to provi...

Страница 18: ...ration see section 2 of the owner guide Important Safety Never cover the heater or obstruct the openings at the base of the heater this could cause overheating and consequent risk of fire What are the...

Страница 19: ...ven if the system external controls timer programmer etc are requesting central heating or domestic hot water If the boiler is ON then the display on the Boiler Control will show a number this being t...

Страница 20: ...layed in two parts i e for E133 Ignition lockout the display will show E1 alternating with 33 How to RESET the Boiler If an error code is displayed a manual reset operation may be required A list of e...

Страница 21: ...Boiler checklist If your boiler is not working or not working correctly please check the following before calling Heateam Make sure the gas supply is turned ON Check if other gas appliances are workin...

Страница 22: ...refront to prevent damage due to over heating If it operates due to an obstruction in the airflow the firefront must be turned off and allowed to cool for 15 minutes and the obstruction removed before...

Страница 23: ...heateam the service division of Baxi Heating UK Ltd either by completing and returning the registration card or calling our telephone registration line on 0800 032 72 30 It is also a requirement of t...

Страница 24: ...tallation 4 Proof of purchase If you do not have the Serial number Note details 1 3 can be found on the last page of this guide What this warranty covers Free of charge repair or replacement of compon...

Страница 25: ...third party repair or replacement costs that we haven t been told about or agreed with you in advance Compensation or consequential losses e g loss of earnings business losses stress and inconvenience...

Страница 26: ...NSIDE THIS BOX Boiler Model B A X I B E R M U D A B B U 1 5 H E Boiler Serial number Can be found on the information label See figure 2 D D M M Y Y Date of Installation Installer Details Block Capital...

Страница 27: ...on the information label See figure 3 A LABEL CONTAINING THE FIREFRONT SERIAL NUMBER MAY HAVE BEEN PLACED INSIDE THIS BOX Brand Please tick Baxi Valor Wonderfire Other D D M M Y Y Date of Installatio...

Страница 28: ...Baxi Heating U K Limited 2009...