5.0 Installation
15
5.2
Fan Outlet Restrictor
(30, 40, 50, 60, 70 and 80)
Rear Flue only up to 500mm (19
5
/
8
in)
1. Release the four latches holding the
combustion box door (Fig 18). Remove the
combustion box door by pulling forward (Fig. 16).
2. Release the 5-pin electrical plug connecting
the pressure switch and fan (Fig. 17). Withdraw
the fan assembly by pulling forwards from the
top edge (Fig. 16).
3. Take the sheetmetal restrictor (supplied in the
kit of parts), check that the number stamped on
the restrictor matches the appliance (e.g. 50
stamped on the restrictor is for 50 PF appliance)
4. Fit the restrictor to the fan outlet flange,
bending the 3 lugs equally ensuring the restrictor
seals against the fan outlet flange (Fig. 19).
5. Re-assemble the fan assembly and
combustion box door ensuring that the flexible
tubes from the fan unit to the pressure switch are
routed correctly and that they are not kinked or
flattened (Fig. 19a).
Fan Outlet Flange
Fan Outlet Restrictor
Fig. 17
Fig. 18
Fig. 16
Fig. 19
Flexible Tubes
Fig. 19a